Related Experiment Video
Updated: Jun 30, 2026

Reverse Total Shoulder Arthroplasty
Published on: July 5, 2011
Aseptic revision from one rotating-hinge to another rotating-hinge prosthesis - how good are the results?
Benedikt Paul Blersch1,2, Florian Hubert Sax3, Bernd Fink4,5
1Department of Joint Replacement, General and Rheumatic Orthopaedics, Orthopaedic Clinic Markgröningen gGmbH, Markgröningen, Germany. bblersch@bgu-tuebingen.de.
Introduction:
Evidence on the outcome of aseptic exchange of rotating-hinge prosthesis is missing in the literature. This study aimed to evaluate implant survival, complication rates, and clinical outcomes following revision of a rotating-hinge prosthesis to another rotating-hinge prosthesis with anatomical axis.
Materials And Methods:
Between March 2014 and Juli 2023 62 cases of aseptic exchange of a rotating-hinge prosthesis were performed at a tertiary medical center in Germany. In this retrospective study, all patients were contacted for clinical follow-up and prosthesis survival. Implant survival was analyzed using the Kaplan-Meier method, and clinical outcomes were assessed using the Knee Society Score.
Results:
The 5-year implant survival rate was 83.4% (73.2-93.6, 95%-CI) for revision due to any reason, 85.1% (75.3-94.9, 95%-CI) for aseptic failure and 98.0% (94.1-100.0, 95%-CI: ) for septic failure. The estimated 10-year survival rates were 73.2% (59.2-87.1%; 95%-CI), 78.0% (65.1-90.9%; 95%-CI), and 93.9% (85.3-100.0%; 95%-CI), respectively. Improvements were observed in all KSS subdomains except for the Patient Expectation Score.
Conclusions:
The exchange of a rotating-hinge prosthesis, using metaphyseal cones when indicated for bone defects, yields implant survival and complication rates comparable to those of primary rotating-hinge prosthesis implantation. However, clinical outcome scores tend to be lower than those reported for first-time implantation of rotating-hinge prostheses.
More Related Videos
07:45The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
Related Concept Videos
Restarting Stalled Replication Forks
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Deformation in a Circular Shaft
Plastic Deformation in Circular Shafts