Related Experiment Video
Updated: Jan 7, 2026

Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
Validation of quantitative perfusion cardiovascular magnetic resonance employing deconvolution techniques with Tofts,
Masafumi Takafuji1, Masaki Ishida1, Yasutaka Ichikawa1
1Department of Radiology and Mie University Hospital, Tsu, Mie, Japan.
Background:
Quantitative perfusion cardiovascular magnetic resonance (QP-CMR) allows the generation of pixel-wise myocardial blood flow (MBF) maps using model-based deconvolution with several models including Tofts, modified-Tofts, and Fermi function models. However, the accuracy of pixel-wise MBF mapping has not been fully investigated in humans. The aim of this study was to evaluate the accuracy of advanced QP-CMR using 15O-water positron emission tomography (PET) as a reference.
Methods:
Thirty-nine patients (29 men, 68±11years) with known or suspected coronary artery disease underwent both CMR including stress and rest QP-CMR and 15O-water PET at a median interval of 13 days. QP-CMR was performed using dual-sequence technique and a single bolus of gadolinium contrast agent during adenosine triphosphate stress and at rest. MBF maps were generated using three different model-based deconvolution techniques as follows: Tofts, modified-Tofts, and Fermi function models. Agreement of MBF and myocardial perfusion reserve (MPR) between QP-CMR and 15O-water PET was evaluated using Pearson's correlation, Bland-Altman analysis, and intraclass correlation (ICC). The ability of CMR-derived stress MBF and MPR to detect PET-defined abnormal myocardial perfusion (stress MBF ≤2.3 mL/min/g and MPR ≤2.5) was evaluated by receiver operating characteristic (ROC) analysis.
Results:
CMR-derived MBF showed a good linear correlation with 15O-water PET-derived MBF in each of the Tofts, modified-Tofts, and Fermi function models (r = 0.776, 0.752, 0.784, respectively; p<0.001 each) at the patient level. Bland-Altman analysis demonstrated measurement biases for MBF between CMR and 15O-water PET of 0.31±0.70, 0.05±0.63, and 0.26±0.68 mL/min/g for the Tofts, modified-Tofts, and Fermi function models, respectively. ICCs were 0.734, 0.747, and 0.750, respectively. The area under the ROC curves for stress MBF derived from the Tofts and Fermi function models (0.921 and 0.914, respectively) was significantly higher than that derived from the modified-Tofts model (0.861; p = 0.003 for both). However, there was no significant difference between the Tofts and Fermi function models (p = 0.618).
Conclusion:
Advanced QP-CMR using three different model-based deconvolution techniques demonstrated strong agreement with 15O-water PET. Of these techniques, the Fermi function and Tofts models were more effective in detecting abnormal myocardial perfusion as determined by 15O-water PET. Considering our results, the model complexity, and its technical availability, the Fermi function model may possess a practical advantage.
More Related Videos
05:56Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Magnetic Resonance Imaging