IHBA-optimized DR-SE-NPCNet for robust open-circuit fault diagnosis in three-level NPC inverters under mixed and
Qisheng Liu1, Changxi Chen2, Honglin Ouyang2
1College of Electrical and Information Engineering, Hunan University, Changsha, 410082, China. liuqisheng@hnu.edu.cn.
Abstract:
Open-circuit faults (OCFs) in three-level neutral-point-clamped (NPC) inverters can severely degrade power quality and compromise system reliability. However, existing diagnostic methods often exhibit performance degradation under mixed operating conditions and strong noise, and they remain highly sensitive to hyperparameter settings. To address these issues, this paper proposes an integrated model-optimization framework that couples a lightweight diagnostic network, DR-SE-NPCNet, with an improved honey Badger algorithm (IHBA) for global hyperparameter tuning. DR-SE-NPCNet preserves full temporal resolution through a temporal resolution preserving-temporal dilation (TRP-TD) backbone and enhances discriminative representations using a residual and squeeze-and-excitation-calibrated fusion (ReSE-CF) module. IHBA further stabilizes and improves the model by enabling efficient and robust hyperparameter optimization. Experiments on a hardware NPC inverter platform demonstrate that the proposed method achieves 92.83-96.94% accuracy under 10 dB noise and mixed variations in load level, modulation index, DC-bus voltage, and output frequency, outperforming conventional CNN-based approaches. With IHBA optimization, diagnostic accuracy is further increased by an additional 2-3%. These results confirm that the integrated DR-SE-NPCNet and IHBA framework provides a robust and high-accuracy solution for OCF diagnosis under severe noise and mixed operating conditions.
Related Concept Videos
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Power System Three-Phase Short Circuits
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Fault Types
For line-to-line faults occurring between phases B and C, the...