This study provides a robust nano-liquid chromatography-tandem mass spectrometry (LC-MS/MS) workflow for deep proteome profiling. The optimized method ensures high-throughput, reliable protein identification essential for large-scale life science experiments.
Area of Science:
- Proteomics
- Analytical Chemistry
- Biotechnology
Background:
- Nano-liquid chromatography-mass spectrometry (LC-MS/MS) is crucial for shotgun proteomics, offering high separation power and sensitivity.
- Establishing robust and reliable LC-MS/MS workflows for large-scale proteomics remains challenging.
Purpose of the Study:
- To provide a detailed protocol for establishing nano-LC-MS/MS workflows for comprehensive, untargeted deep proteome profiling.
- To optimize a data-independent acquisition (DIA)-parallel accumulation-serial fragmentation (PASEF) method for high-throughput proteomics.
- To demonstrate the robustness and reproducibility of the developed workflow.
Main Methods:
- Utilized state-of-the-art second-generation micropillar-array column technology for enhanced chromatographic separation.
- Developed a straightforward workflow for data-independent acquisition (DIA)-parallel accumulation-serial fragmentation (PASEF) analysis, including ESI source optimization.
- Explored segmented gradients and MS-compatible surfactants for improved analytical performance.
Main Results:
- Demonstrated a trade-off between analysis time and chromatographic resolution impacting peptide and protein identification.
- Achieved consistent identification of 7558 protein groups with high repeatability (CV = 0.3%).
- Maintained high reproducibility in peptide retention times (mean CV = 0.2%) and system pressure (CV = 0.4%) over 21 analyses.
Conclusions:
- The developed nano-LC-MS/MS workflow provides a robust and reproducible method for deep proteome profiling.
- This protocol facilitates reliable, large-scale proteomics studies in life sciences.
- The optimized DIA-PASEF method enhances throughput and data quality in proteomic analyses.