Abstract:
Mobile sound level applications have been proposed as potential adjuncts for conventional sound level meters (SLM) in noise measurement. However, their performance remains uncertain in the manufacturing industry setting. This study was aimed to determine the validity, reliability, and agreement of the NIOSH SLM app in measuring noise in the manufacturing industry with reference to conventional SLM. A total of 93 samples were collected from five machineries. An iPhone 12 Pro and an iPhone 12 mini, each installed with the latest version of NIOSH SLM app, were tested against the conventional SLM (as gold standard). Three noise parameters, namely the average noise level (i.e., LAeq), maximum sound level (i.e., LMax) and 8-hour time-weighted average (i.e., TWA-8 h) were measured by all devices. Concurrent validity was assessed using Pearson's correlation coefficient while two-way mixed effects intraclass correlation coefficient (ICC 3,1) was used to assess the intra-rater reliability. The agreement in the noise parameters measured was assessed using the Bland-Altman plot. The NIOSH SLM app demonstrated high concurrent validity, as measured by Pearson's correlation (p < 0.001) and moderate-to-good reliability, as measured by ICC 3,1 (p < 0.001) in all three noise parameters measured. The LAeq and TWA-8 h measured by the NIOSH SLM app were in agreement with the conventional SLM, with the exception of LMax. The NIOSH SLM app is valid and reliable in measuring noise when compared to conventional SLM. Two out of three noise parameters measured by NIOSH SLM app were agreeable to that measured by the conventional SLM.
More Related Videos
08:25Continuous Measurement of Biological Noise in Escherichia Coli Using Time-lapse Microscopy
Published on: April 27, 2021
07:13Modified Experimental Conditions for Noise-Induced Hearing Loss in Mice and Assessment of Hearing Function and Outer Hair Cell Damage
Published on: February 10, 2023
Related Concept Videos
Applications of Logarithms
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
Pipe Flowrate Measurement
The orifice meter is a simple,...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Electronic Distance Measuring Instruments