Comparison of three rebound tonometers in rabbits
Chenghai Wang1, Yunhao Su1, Fushan Shi2
1School of Mechanical Engineering, Zhejiang Sci-Tech University, Hangzhou, 310018, China.
None:
This study compared the performance of three rebound tonometers (iFalcon Tonovet, iCare Tonovet Plus, Reichert Tono-Vera Vet) for measuring intraocular pressure (IOP) in normal rabbit eyes, where a wide range of intraocular pressure (approx. 11-86 mmHg) was established and regulated via an intracameral needle connected to a saline manometer. Intraocular pressure measurements were performed on 10 eyes of New Zealand White rabbits using each of the three tonometers mentioned above. Measurements were taken at pressures ranging from 11 to 86 mmHg, yielding a total of 298 datasets. Statistical analysis of the intraocular pressure values obtained: iFalcon (32.5 ± 13.9 mmHg), iCare (33.6 ± 14.3 mmHg), Reichert (31.4 ± 12.0 mmHg) (p = 0.138). High overall agreement was observed (R2 0.95-0.98). However, trend differences existed: iFalcon slightly underestimated iCare, especially at higher IOP; Reichert read higher than iFalcon below 23 mmHg but lower above; Reichert also read higher than iCare below 18 mmHg but lower above. The novel iFalcon demonstrated stable performance. All three devices show good agreement for rabbit IOP monitoring, but clinicians should be aware of trend differences at low and high pressures, potentially applying corrections when switching devices during longitudinal studies.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure