Pilot Study on Risk Perception in Practices with Medical Cyclotrons in Radiopharmaceutical Centers in Latin American
Frank Montero-Díaz1,2, Antonio Torres-Valle3, Ulises Jauregui-Haza1,4
1Area of Basic and Environmental Science, Instituto Tecnológico de Santo Domingo (INTEC), Santo Domingo 10602, Dominican Republic.
None:
Practices with medical cyclotrons to produce PET radiopharmaceuticals in Latin America represent a technological advance for the diagnosis and treatment of diseases such as cancer, but they involve occupational risks due to exposure to ionizing radiation. This study evaluates the perception of risk in 46 radiopharmacy service workers in 13 countries in the region (Argentina, Bolivia, Brazil, Chile, Colombia, Costa Rica, Cuba, Ecuador, Mexico, Peru, Portugal, Dominican Republic and Venezuela), analyzing differences by gender and age. The questionnaire, validated by reliability analysis (Cronbach's coefficient α > 0.7), was statistically analyzed with means, standard deviations (SD) and standard errors (SE), 95% confidence intervals (Student's t-distribution), and coefficients of variation (CV) to assess the dispersion of each variable. The results reveal general underestimation in dimensions such as reversibility of consequences (SD = 0.7142, SE = 0.1053) and familiarity (SD = 0.8410, SE = 0.124), promoting complacency, while immediacy of consequences shows overestimation (SD = 0.9760, SE = 0.1439), amplifying anxiety. By gender, women tend to overestimate (e.g., immediacy = 2.5) and men underestimate (e.g., confidence = 1.78); by age, young people (26-45 years old) overestimate more than older people (≥46 years old). These deviations, with high QoL indicating heterogeneity, suggest interventions such as continuous training, real-time monitoring, and communication campaigns to balance perception. Practical recommendations include job rotations to reduce underestimation due to familiarity and simulations to mitigate emotional overestimation, which are aligned with IAEA regulations (GSR Part 3, SSG-46) to promote a sustainable safety culture.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...