Related Experiment Video
Updated: Jan 7, 2026

Cell-based Assay Protocol for the Prognostic Prediction of Idiopathic Scoliosis Using Cellular Dielectric Spectroscopy
Published on: October 16, 2013
Adherence and Radiological Outcomes in Braced Adolescents with Idiopathic Scoliosis: A Real-World Study Using Thermal
Samra Pjanić1, Fabio Zaina2, Nikola Jevtić3
1Institute for Physical Medicine, Rehabilitation and Orthopedic Surgery "Dr Miroslav Zotovic", 78000 Banja Luka, Bosnia and Herzegovina.
Abstract:
Background: Bracing is an effective treatment for idiopathic scoliosis (IS), and Adherence is one of the most important factors influencing outcomes. However, evidence on the effectiveness of objective monitoring using thermal sensors in everyday clinical settings remains limited. Objective: To evaluate the impact of Adherence and brace-wearing consistency on short-term outcomes in IS patients during growth in a real clinical setting. Methods: This retrospective cohort study included 114 patients (100 with adolescent idiopathic scoliosis (AIS) and 14 with juvenile idiopathic scoliosis (JIS)) treated with a three-dimensional (3D) rigid brace equipped with a thermal sensor. Adherence was calculated as the ratio of actual to prescribed wear time; consistency was defined using the interquartile range (IQR) of daily wear time (IQR ≤ 1 h = consistent). Cobb angle was measured at baseline, in-brace, and after 6 months. Logistic regression, receiver-operating characteristic (ROC) analysis, and general linear model (GLM) analyses were performed, supported by sensitivity analyses, to assess model robustness. Results: Mean Adherence was 85.3 ± 18.9%; high Adherence was observed in 71.4% of JIS and 57.0% of AIS patients, while 19.3% showed high consistency. In-brace correction averaged 52.5 ± 23.2% (68.1% JIS vs. 50.3% AIS; p = 0.007). At 6 months, 55% improved, 42% were stable, and 3% worsened. Adherence was the only significant predictor of consistency (OR = 1.511; 95% CI 1.181-1.933; p = 0.001). The ROC analysis showed excellent discriminative ability (Area Under the Curve (AUC) = 0.908). Adherence category (p = 0.041) and Risser stage (p = 0.041) were significant predictors of short-term outcome. Conclusions: Adherence and brace-wearing consistency are key predictors of short-term bracing outcomes in IS. Objective monitoring with thermal sensors enables precise tracking, improves patient engagement, and supports individualised treatment.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...