Evaluating implant properties on the implant stability of immediately loaded implants
Md Kafeel Ahmed1, Harinder Singh Mangat2, Ananya Bhargava3
1Department of Periodontology, MNR Dental College and Hospital, Sangareddy, Hyderabad Telangana, India.
Abstract:
Immediate implantation of dental implants provides a shortened period of treatment at the cost of high stability requirements. Therefore, it is of interest to assess the impact of implant diameter, length and surface texture on the implant stability quotient (ISQ) of 40 patients on fibroblastic posterior mandibular implants. Primary and secondary ISQ values were much higher in the rough surfaces and wider diameters (p < 0.05), whereas the length of the implants did not have much influence. There was an improvement in ISQ in all groups after 12 weeks. Thus, the success of immediate loading depends on surface roughness and diameter.