Aortic Compliance After Root Replacement With Decellularized Homografts Versus in Donor Age-Matched Healthy Controls

Tomislav Cvitkovic1, Alexander Horke1, Dmitry Bobylev1

  • 1Department of Cardiac, Thoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, 30625, Germany.

Insights

Patients receiving decellularized aortic homografts showed reduced ascending aorta compliance compared to healthy controls. Further follow-up is needed to understand long-term effects of these aortic homografts.

Area of Science:

  • Cardiovascular Research
  • Biomaterials Science
  • Medical Imaging

Background:

  • Decellularized aortic homografts are used in cardiovascular surgery.
  • Understanding their long-term biomechanical properties is crucial.

Purpose of the Study:

  • To evaluate the compliance and blood flow of the ascending aorta in patients with decellularized aortic homografts.
  • To compare these parameters with age-matched healthy controls.

Main Methods:

  • Retrospective electrocardiography-gated cine balanced steady-state free precession magnetic resonance imaging was used.
  • Time-resolved phase-contrast sequences assessed relative area change and pulse wave velocity for compliance.
  • Maximum blood flow velocity was also determined.

Main Results:

  • Patients with decellularized aortic homografts exhibited significantly lower relative area change in the proximal ascending aorta compared to controls (26% vs 38%, p < 0.001).
  • Maximum blood flow velocity was significantly higher in the proximal ascending aorta of homograft patients (168 cm/s vs 115 cm/s, p = 0.009).
  • No significant difference in compliance was found in the distal ascending aorta.

Conclusions:

  • Decellularized aortic homografts are associated with reduced proximal ascending aorta compliance.
  • This may be due to the decellularization process or graft degeneration.
  • Long-term follow-up data are essential to understand the in vivo effects of these grafts.
Abstract