Signal Quality Assessment and Reconstruction of PPG-Derived Signals for Heart Rate and Variability Estimation in
Ruimin Gao1, Carl S Miller2, Brian T W Lin2
1School of Psychology, Georgia Institute of Technology, Atlanta, GA 30332, USA.
None:
Electrocardiography (ECG) is widely recognized as the gold standard for measuring heart rate (HR) and heart rate variability (HRV). However, photoplethysmography (PPG) presents notable advantages in terms of wearability, affordability, and ease of integration into consumer devices, despite its susceptibility to motion artifacts and the absence of standardized processing protocols. In this study, we review current ECG and PPG signal processing methods and propose a signal quality assessment and reconstruction pipeline tailored for dynamic, in-vehicle environments. This pipeline was evaluated using data gathered from participants riding in an automated vehicle. Our findings demonstrate that while blood volume pulse (BVP) derived from PPG can provide reliable heart rate estimates and support extraction of certain HRV features, its utility in accurately capturing high-frequency HRV components remains constrained due to motion-induced noise and signal distortion. These results underscore the need for caution in interpreting PPG-derived HRV, particularly in mobile or ecologically valid contexts, and highlight the importance of establishing best practices and robust preprocessing methods to enhance the reliability of PPG sensing for field-based physiological monitoring.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...