Influence of Lens Systematic Errors on Autocollimator Angle Measurement: Theoretical and Experimental Explanations
Yuechao Li1,2, Shuo Zhang3, Di Chang1,2
1Center of Ultra-Precision Optoelectronic Instrument Engineering, Harbin Institute of Technology, Harbin 150080, China.
Abstract:
Autocollimators are widely used for sensor calibration. It is crucial to suppress systematic errors and enhance the measurement accuracy of autocollimators. However, the influence mechanism of systematic errors originating from the collimator objective-such as aberrations, and particularly the coupled effect of aberrations and assembly deviation-on measurement accuracy is not well understood. By switching between the perspectives of ray tracing and aberration, we analyzed the influence mechanism of aberrations. The results indicate that only coma aberrations of various orders affect the accuracy. Then we applied nodal wave aberration theory and found that the influence of assembly deviation is a factor only related to the aberration under a certain offset (composed of translational and rotational components). In this work, we defined the sensitivity of assembly deviation as the ratio of this factor and the offset. In the experimental part based on a homemade autocollimator, the maximal errors of yaw angle are decreased from 2.09 arcsecs to 1.41 arcsecs, while the one of pitch angle is decreased from 2.32 arcsecs to 1.63 arcsecs, within a measuring interval of ±500 arcsecs. The sensitivity of assembly deviation of the collimator objective used is 0.004 arcsec per micron, which agrees with the theoretical analysis.
More Related Videos
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Related Concept Videos
Random and Systematic Errors
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Uncertainty in Measurement: Accuracy and Precision
Common Leveling Mistakes and Errors
Distance Corrections
Focusing of Light in the Eye