Multi-channel spectral sensor-based instrument as an alternative to the Agtron for predicting coffee roast degree

Diang Sagita1, Sutrisno Suro Mardjan2, Slamet Widodo2

  • 1Agricultural Engineering Science, Graduate School, IPB University, Bogor 16680, Indonesia; Research Center for Equipment Manufacturing Technology, National Research and Innovation Agency, South Tangerang 15314, Indonesia.

Food Chemistry
|December 31, 2025
PubMed

Related Concept Videos

Classification of Titrimetric Analysis Based on Reaction Types01:01

Classification of Titrimetric Analysis Based on Reaction Types

Titrimetric analysis in solution chemistry involves measuring the volume of solutions and is often called volumetric analysis. The standard solution of known concentration in the burette is called the titrant, whereas the solution of unknown concentration in the flask is called the analyte, or titrand. Titrimetric analyses can be classified into four types based on the reactions between the titrant and analyte.
Titrations between an acid and a base lead to neutralization reactions that form...
1.5K
Classification of Signals01:30

Classification of Signals

In signal processing, signals are classified based on various characteristics: continuous-time versus discrete-time, periodic versus aperiodic, analog versus digital, and causal versus noncausal. Each category highlights distinct properties crucial for understanding and manipulating signals.
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...
1.3K
Chromatographic Methods: Classification01:12

Chromatographic Methods: Classification

Chromatographic techniques are classified in three ways: the classification is based on the physical state of the stationary and mobile phases, how the mobile phase and the stationary phase contact each other, or through the chemical or physical processes that isolate the components of the sample. Typically, the mobile phase is either a liquid or gas, while the stationary phase is either a solid or a liquid layer applied to a solid surface.
Chromatographic techniques are typically named by...
3.6K
Classification of Systems-I01:26

Classification of Systems-I

Linearity is a system property characterized by a direct input-output relationship, combining homogeneity and additivity.
Homogeneity dictates that if an input x(t) is multiplied by a constant c, the output y(t) is multiplied by the same constant. Mathematically, this is expressed as:
533
IR and UV–Vis Spectroscopy of Aldehydes and Ketones01:29

IR and UV–Vis Spectroscopy of Aldehydes and Ketones

Infrared spectroscopy, also known as vibrational spectroscopy, is mainly used to determine the types of bonds and functional groups in molecules. In aldehydes and ketones, the carbonyl (C=O) bond shows an absorption around 1710 cm-1. The C=O bond vibration of an aldehyde occurs at lower frequencies than that of a ketone. In addition to the C=O absorption in an aldehyde, the aldehydic C–H bond also gives two peaks in the 2700–2800 cm-1 range. This absorption, coupled with the...
7.2K
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
990