Skin-conformal PMN-PT ultrasonic sensor for cuffless blood pressure sensing via eutectic solder integration
Syed Turab Haider Zaidi1,2, Dong Hun Kim3, Muhammad Ali Shah1
1Department of Bionic Machinery, Korea Institute of Machinery and Materials, Daejeon, 34103, South Korea.
None:
Wearable ultrasonic systems are emerging as promising tools for noninvasive cardiovascular monitoring, enabling the real-time assessment of vascular dynamics without the need for cuff-based measurements. However, the integration of high-performance piezoelectric materials into flexible, skin-conformal arrays poses challenges in terms of mechanical stretchability, acoustic fidelity, and scalability. In this study, we present a flexible 5 × 4 ultrasonic transducer array (UTA) based on 1-3 lead magnesium niobate-lead titanate (PMN-PT) composite elements for continuous blood pressure monitoring. To achieve reliable integration, we employed a dual-sided eutectic solder bonding method using an Sn-Bi alloy to ensure low-temperature attachment without depolarization. The fabricated UTA operates at a center frequency of 6.0 MHz with an acceptance angle of 45°, enabling acoustic signal acquisition under varying angular conditions. Time-of-flight simulations and in vitro testing of vascular phantoms demonstrated the accurate tracking of vessel diameters and the estimation of real-time blood pressure. The UTA achieved systolic and diastolic pressure measurements within 4 mmHg of those of a commercial reference sensor. These results highlight the feasibility of scalable and flexible ultrasound systems for wearable hemodynamic sensors, suggesting their potential for next-generation point-of-care diagnostics.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...