Related Experiment Video
Updated: Jun 20, 2026

Rapid Homogeneous Detection of Biological Assays Using Magnetic Modulation Biosensing System
Published on: June 13, 2010
Fishnet-like 2D magnetic nanozyme probe enables ultrasensitive bedside immunodiagnosis of bone infection pathogens
Chongwen Wang1,2, Changyue Xu2, Jiaxuan Li2
1Department of Orthopedics, Guang Dong Engineering Technology Research Center of Functional Repair of Bone Defects and Biomaterials, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Southern Medical University, Guangzhou, 510080, China.
Abstract:
Rapid, early, and accurate bedside diagnosis of bone infections is an urgent clinical need that remains unmet. Here, we present a fishnet-like two-dimensional magnetic nanozyme (FGDAI) that integrates three functional modules: a monolayer graphene oxide substrate providing a large reaction interface; an Fe3O4 interlayer conferring efficient magnetic enrichment; and two dense layers of Au@Ir nanoparticles furnishing abundant catalytic sites that act synergistically with the Fe3O4 to enable catalytic enhancement. This architecture delivers multiple signal amplification-"large reaction interface, magnetic enrichment, synergistic enhancement"-within an immunochromatographic assay (ICA), effectively overcoming the sensitivity and robustness limitations of traditional colorimetric ICAs when challenged by complex clinical matrices. In addition, wheat germ agglutinin (WGA) was immobilized on the 2D FGDAI surface via lyophilization as a universal peptidoglycan recognition molecule, enabling efficient, broad-spectrum bacterial binding and thereby mediating ultrasensitive, simultaneous ICA detection of two important bone-infection pathogens (Staphylococcus aureus and Pseudomonas aeruginosa). FGDAI-WGA-ICA completes testing in under 25 min with a visual limit of detection of 10 cells/mL, exhibiting high sensitivity and specificity for the target pathogens. Moreover, validation in a cohort of 83 synovial fluid samples showed high concordance with clinical reference methods, supporting its potential for real-time, bedside diagnosis of bone infections.
More Related Videos
09:04Foodborne Pathogen Screening Using Magneto-fluorescent Nanosensor: Rapid Detection of E. Coli O157:H7
Published on: September 17, 2017
09:58Computer Numerical Control Micromilling of a Microfluidic Acrylic Device with a Staggered Restriction for Magnetic Nanoparticle-Based Immunoassays