Purpose:
Conventional handheld pH meters have measurement limitations. Therefore, this study aimed to continuously measure the salivary pH at two intraoral locations using a newly developed sensor system.
Methods:
In this pilot study, we developed custom-made intraoral mouthguards (MG) with two pH sensors in the anterior region (Channel 1: Ch1) and the buccal side of the maxillary molar (Channel 2: Ch2) to continuously monitor salivary pH at two different locations in the oral cavity.
Results:
The coefficient of determination (R2) for all MG sensor measurements was ≥0.99, with a high level of accuracy. Both sensor channels exhibited similar mean pH values for standard solutions, with small and constant variations. However, notable unstable differences in intraoral measurements were observed during rehydration owing to positional differences. Nonetheless, the MG sensors demonstrated excellent reliability with consistently high Intraclass Correlation Coefficients ranging from 0.977 to 0.999.
Conclusions:
This pilot study provides valuable insights into salivary pH fluctuations, particularly during exercise, through continuous measurements using a sensor system for the simultaneous acquisition of real-time data from different anatomical sites. These results emphasize the potential of developing an intraoral sensor system that can detect subtle variations in salivary pH.
More Related Videos
07:09Use of a High-throughput In Vitro Microfluidic System to Develop Oral Multi-species Biofilms
Published on: December 1, 2014
08:25Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
Published on: August 27, 2021
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Salivary Glands and Saliva