Low-concentration contrast abdominopelvic CT: A comparison with high-concentration contrast CT image quality
Sungjin Yoon1,2, Joo-Hwan Park3, Sun Jin Sym3
1Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea.
Objective:
This study aimed to compare abdominopelvic computed tomography (APCT) image quality using low and high concentrations of a contrast agent in patients with cancer via a noninferiority design.
Methods:
This study prospectively included 99 patients with malignancies who underwent dual-source APCT following injection of 1.5 mL/kg of iohexol 270 (low-concentration group). The control group included patients who were retrospectively matched 1:1 based on weight, body mass index, and sex. These patients (high-concentration group) received 1.1 or 1.2 mL/kg of iohexol 350, reconstructed at two tube voltages (80 kVp and 80/Sn150 kVp). The noninferiority margins were set at -0.21 for overall image quality. Two radiologists blindly and independently analyzed the subjective and objective image quality of matching focal lesions.
Results:
A total of 198 patients with 102 focal lesions (44 liver lesions, 58 renal lesions) were assessed. The total iodine amount was slightly higher in the low-concentration group than in the high-concentration group without significant differences (24580.0 ± 3745.6 vs. 24190.2 ± 3954.3 mg I/mL; p = 0.051). Overall image quality did not differ significantly between the groups (2.6 ± 0.5 vs. 2.6 ± 0.5 on 80 kVp; p = 0.484; 3.4 ± 0.5 vs. 3.4 ± 0.6 on 80/Sn 150 kVp, p = 0.891). Margin sharpness and conspicuity also showed no significant differences between the low- and high-concentration groups at 80 kVp (p = 0.890, 0.103) and 80/Sn 150 kVp images (p = 0.278, 0.369). Liver attenuation was slightly higher in the low-concentration than in the high-concentration group (80 kVp, 127.3 ± 16.8 vs. 122.4 ± 13.0, p = 0.013; 80 kVp/Sn 150 kVp, 108.2 ± 13.3 vs. 104.5 ± 10.9, p = 0.025). No major or minor adverse reactions occurred during or immediately after contrast agent injection in either group. Five patients in the low-concentration group experienced below-average vascular pain.
Conclusions:
The low-concentration group offered noninferior overall image quality compared to the high-concentration group among patients with cancer.
More Related Videos
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...