Related Experiment Video
Updated: Jan 13, 2026

Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
A stability-indicating RP-HPLC method for the simultaneous quantification of brimonidine tartrate and timolol maleate
1Department of Applied Pharmaceutical Sciences and Clinical Pharmacy, Faculty of Pharmacy, Isra University, P.O. Box 22, Amman, 11622, Jordan. aktham.mestareehi@med.wayne.edu.
Abstract:
A robust, rapid, and reproducible reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the simultaneous quantification of Brimonidine Tartrate and Timolol Maleate (Combigan) in ophthalmic dosage forms. Chromatographic separation was achieved on a Supelco Discovery C18 column (25 cm × 4.6 mm, 5 μm) maintained at ambient temperature, employing isocratic elution with two mobile phases: phase A (buffer at pH 7.0 containing 30 mM triethylamine) and phase B (acetonitrile) in a ratio of 80:20. The flow rate was set at 1.0 mL/min, and detection was performed at 245 nm and 295 nm using a diode array detector (DAD). Method validation, conducted in accordance with ICH Q2(R1), USP, and FDA guidelines, confirmed excellent linearity over the ranges of 0.24-500 ppm for Brimonidine Tartrate and 0.60-1250 ppm for Timolol Maleate. Accuracy results ranged from 99.42% to 99.82% for Brimonidine Tartrate and from 98.71% to 101.10% for Timolol Maleate. Relative standard deviations (RSDs) for precision, specificity, and robustness were all below 2%, demonstrating the method's consistency and reliability. Additionally, the limits of detection (LOD) were determined to be 0.08 ppm for Brimonidine Tartrate and 0.20 ppm for Timolol Maleate, while the limits of quantification (LOQ) were 0.24 ppm and 0.60 ppm, respectively. Forced degradation studies under various stress conditions, including acid and base hydrolysis and hydrogen peroxide oxidation, demonstrated that the method successfully separated Brimonidine Tartrate and Timolol Maleate from their degradation products, confirming its stability-indicating capability. Notably, both drugs remained stable under thermal and photolytic stress; however, Timolol Maleate was significantly more prone to degradation under strong hydrolytic and oxidative conditions, underscoring the need for stringent control during formulation and storage. Additionally, the three complementary green analytical chemistry (GAC) metrics were evaluated. The method achieved an Eco-Scale score of approximately 75. The GAPI pictogram for this method showed a mixture of green and yellow zones. The AGREE evaluation yielded a score of 0.57 (out of 1.0), indicating moderate greenness. Overall, this method effectively quantified both active pharmaceutical ingredients without interference from excipients or degradation products, supporting its suitability for routine quality control and stability testing of combined ophthalmic formulations.
More Related Videos
08:57Sample Extraction and Simultaneous Chromatographic Quantitation of Doxorubicin and Mitomycin C Following Drug Combination Delivery in Nanoparticles to Tumor-bearing Mice
Published on: October 5, 2017
07:29HPLC Coupled with Chemical Fingerprinting for Multi-Pattern Recognition for Identifying the Authenticity of Clematidis Armandii Caulis
Published on: November 11, 2022
Related Concept Videos
Therapeutic Drug Monitoring: Drug Analysis Methods
Clinically Relevant Drug Product Specifications: Methods of Establishment
Measurement of Bioavailability: Pharmacokinetic Methods
Measurement of Bioavailability: Pharmacodynamic Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Noncompartmental Analysis: Miscellaneous Pharmacokinetic Parameters
One key aspect of the noncompartmental approach is determining a drug's total clearance. This can be done by dividing the drug dose by the area under the concentration-time curve from zero to infinity. The area under the concentration-time curve represents the drug's...