A novel approach for high impedance fault detection in resonant grounding systems based on statistical
Qinglin Meng1,2,3, Yuan Gao4,5, Sheharyar Hussain6
1Green Power Research Institute, Tianjin Renai College, Tianjin, 301636, China. qinglin.meng@ieee.org.
Scientific Reports
|January 6, 2026
Abstract
No abstract available in PubMed .
Keywords:
Distribution networkFault detectionFaulty line selectionHigh impedance faultResonant grounding systemMore Related Videos
07:02Investigating the Potential of Singly Curved Thin Piezoelectric Transducers for Energy Harvesting and Structural Health Monitoring
Published on: November 14, 2025
750
05:11High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
Published on: June 27, 2025
643
Related Concept Videos
Fault Types
399
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
399
Line Protection with Impedance Relays
430
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
430
Series R—L Circuit Transients
370
In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
370
Power System Three-Phase Short Circuits
516
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
516
Three-Phase Short Circuit—Unloaded Synchronous Machine
663
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
663
Parallel RLC Circuits
1.6K
Street lamps equipped with RLC surge protectors are an excellent example of applying circuit analysis in practical scenarios. These surge protectors safeguard the lamp's components against sudden voltage spikes.
A simplified parallel RLC circuit model with a DC input source generating a step response is employed in this context. When the switch is turned on, Kirchhoff's current law is applied, leading to a second-order differential equation.
A simplified parallel RLC circuit model with a DC input source generating a step response is employed in this context. When the switch is turned on, Kirchhoff's current law is applied, leading to a second-order differential equation.
1.6K