Related Experiment Video
Updated: Jan 13, 2026

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Smart swim goggles accurately measure heart rate during swim training: A criterion validation study
Aidan Kits1, Neha Chhatre Elder1, Dan Eisenhardt2,3
1Department of Biomedical Physiology and Kinesiology and Sports Analytics Group, Simon Fraser University Burnaby, BC, Canada.
None:
Accurately measuring training intensity in swimming remains a challenge due to the limited availability of scientifically validated monitoring devices. The measurement of heart rate (HR), for example, would enable the calculation of HR-based training loads. The FORM Smart Swim 2 goggles measure HR via a temple-mounted optical sensor and enable real-time HR feedback. However, the goggles' HR measurement function has yet to be validated. Twenty-five experienced recreational swimmers simultaneously wore the goggles and a criterion chest-strap (Garmin HRM-Swim) during the completion of an assigned workout. Agreement was assessed at four levels of data aggregation: individual data points, intervals, main-sets, and whole-workouts. Respective mean HR (HRmean) from the goggles and criterion chest-strap were 136 ± 17 bpm and 135 ± 18 bpm (mean absolute percentage error = 1.0 ± 1.2%). For HRmean, concordance correlation was high (intervals: 0.91, 95%CI: 0.87 to 0.94; whole-workouts: 0.99, 95%CI: 0.99 to 1.0), and fixed bias was low (intervals: -0.23 bpm, 95%CI: -1.2 to 0.78 bpm; whole-workouts: -0.24 bpm; 95%CI: -0.94 to 0.46 bpm). Strong agreement was observed between the goggles and criterion chest-strap for HR measurements, particularly for HRmean. Since HRmean serves as the primary input for HR-based training load metrics, the goggles provide valid data for monitoring swim training.
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...

