The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
Computed tomography analysis of acetabular component anteversion after total hip arthroplasty: A retrospective study
Sang-Min Lee1,2,3, Min Uk Do1,2, Suk-Woong Kang1,2
1Department of Orthopedic Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea.
Abstract:
This study aims to compare the accuracy and reliability of computed tomography (CT) anteversion measurements between the conventional axial plane (CAP) and the functional coronal plane (FCP). We retrospectively examined 68 patients' postoperative CT scans following primary unilateral total hip arthroplasty (THA). PolyWare software, which uses edge detection to determine radiographic anteversion of the acetabular component, served as the reference standard. We measured anatomical anteversion in the CAP and radiographic anteversion in the reformatted FCP using reconstruction software. Reliability was evaluated with the intraclass correlation coefficient. The mean anteversion of the acetabular component in the CAP and FCP CT images were 29.18 ± 6.06° and 21.17 ± 5.38°, respectively. The mean CT anteversion in the FCP was considered accurate owing to its similarity with the reference standard (20.70 ± 4.39°, P = .281). However, the mean CT anteversion in the CAP was significantly different and thus considered less accurate; the CT anteversion in the CAP was larger than that in the FCP, showing a significant linear correlation (R = 0.673, P < .001), with a difference of 8.01°. The intraobserver and interobserver reliabilities were excellent for all measurement methods. Using radiographic anteversion defined by digital image analysis software as the reference standard, the anteversion measurement in the reformatted FCP proved more accurate than in the CAP. The reformatted FCP CT image facilitates precise post-THA anteversion measurement, with the method difference being around 8.01°. This study aids in measuring anteversion via CT.
More Related Videos
08:15Three-Dimensional Preoperative Virtual Planning in Derotational Proximal Femoral Osteotomy
Published on: February 17, 2023
06:28Anterior Cruciate Ligament Transection and Synovial Fluid Lavage in a Rodent Model to Study Joint Inflammation and Posttraumatic Osteoarthritis
Published on: September 2, 2025
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Eccentric Axial Loading in a Plane of Symmetry