Evaluation and optimization of shield design for anterior teeth in the socket shield technique: a finite element
Qianqian Zuo1,2, Haidong Teng1,2, Yuanli Zhang3
1Yibin Institute of Industrial Technology, Sichuan University Yibin Park, Yibin, China.
None:
The socket shield technique (SST) is a promising protocol for immediate implant placement in the anterior esthetic zone, yet the biomechanical impact of shield design parameters across different tooth positions remains unclear. This study investigated how shield geometry influences peri-implant stress distribution in lateral incisors and canines, aiming to support anatomy-driven design strategies. A three-dimensional maxillary model was reconstructed from cone-beam computed tomography of a healthy subject. The left central incisor, lateral incisor, and canine were segmented, and nine finite element models with varying shield length, thickness, and jump gap were established. under time-dependent functional loading. A time-dependent oblique load at 45° was applied, and stress distributions (von Mises, maximum and minimum principal stresses) and displacements of the shield and periodontal ligament (PDL) were evaluated. Results showed that direct transfer of central incisor-based designs yielded suboptimal stress regulation in lateral incisors and canines. Larger jump gaps enhanced stress mitigation in lateral incisors, whereas a shield length of half the root outperformed one-third in canines. Increased shield thickness promoted stress dispersion, but under space constraints, reducing thickness to allow a wider jump gap maintained stability. In conclusion, these findings provide finite element evidence that individualized shield designs are essential to optimize mechanical stability and long-term outcomes in SST.
More Related Videos
07:16Author Spotlight: Development of a Novel Finite Element Analysis Model for Improved Orthognathic Surgical Techniques
Published on: October 20, 2023
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Routh-Hurwitz Criterion II
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first column of the Routh...
The Squeeze Theorem
Methods of Medium Optimization