Related Concept Videos

Poisson's And Laplace's Equation01:25

Poisson's And Laplace's Equation

The electric potential of the system can be calculated by relating it to the electric charge densities that give rise to the electric potential. The differential form of Gauss's law expresses the electric field's divergence in terms of the electric charge density.
Symmetry in Maxwell's Equations01:28

Symmetry in Maxwell's Equations

Once the fields have been calculated using Maxwell's four equations, the Lorentz force equation gives the force that the fields exert on a charged particle moving with a certain velocity. The Lorentz force equation combines the force of the electric field and of the magnetic field on the moving charge. Maxwell's equations and the Lorentz force law together encompass all the laws of electricity and magnetism. The symmetry that Maxwell introduced into his mathematical framework may not be...
Differential Form of Maxwell's Equations01:17

Differential Form of Maxwell's Equations

James Clerk Maxwell (1831–1879) was one of the significant contributors to physics in the nineteenth century. He is probably best known for having combined existing knowledge of the laws of electricity and the laws of magnetism with his insights to form a complete overarching electromagnetic theory, represented by Maxwell's equations. The four basic laws of electricity and magnetism were discovered experimentally through the work of physicists such as Oersted, Coulomb, Gauss, and Faraday.
Phasor Arithmetics01:13

Phasor Arithmetics

Phasors and their corresponding sinusoids are interrelated, offering unique insights into the behavior of alternating current (AC) circuits. One way to understand this relationship is through the operations of differentiation and integration in both the time and phasor domains.
When the derivative of a sinusoid is taken in the time domain, it transforms into its corresponding phasor multiplied by j-omega (jω) in the phasor domain, where j is the imaginary unit, and ω is the angular frequency.
Time and frequency -Domain Interpretation of Phase-lag Control01:21

Time and frequency -Domain Interpretation of Phase-lag Control

Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any finite,...
Improper Integrals: Discontinuous Integrands01:28

Improper Integrals: Discontinuous Integrands

Evaluating Areas Under Curves with DiscontinuitiesA definite integral is considered improper when the integrand is discontinuous at one of the limits of integration. This occurs when the function is undefined or becomes infinite at an endpoint, making the corresponding region under the curve unbounded. Such behavior is commonly associated with vertical asymptotes at the boundary of the interval. To properly define and evaluate these integrals, a limiting process is used to determine whether a...