Fabrication and Characterization of Optical Tissue Phantoms Containing Macrostructure
Published on: February 12, 2018
Design and characterisation of intervertebral disc mimicking phantoms for photoacoustic imaging
Roman Allais1, Valentin Espinas2, Antoine Capart2
1Aix-Marseille University, CNRS, Centrale Méditerranée, IRPHE, Marseille, France.
Abstract:
Photoacoustics has gained momentum as a new medical imaging technique owing to its ability to benefit from good optical contrast and acoustic resolution. To ease transfer into clinical settings and validate the algorithms, calibrated tissue-mimicking materials (TMM) are required. This paper describes a complete photoacoustic characterisation of a line of titanium dioxide (TiO2) doped agarose hydrogels whose optical absorption (490-835 nm), reduced scattering (590-815 nm), isobaric heat capacity, mass density, speed of sound and acoustic attenuation were quantified for an agarose concentration up to 4% w/w and a TiO2 concentration ranging from 0.25 to 1 mg/mL. Empirical constitutive laws as a function of the concentrations of the components were derived, enabling the creation of TMM with tailored properties. Results showed that these phantoms are suitable candidates to mimic the photoacoustic properties of various soft tissues including intervertebral discs (IVD). Photoacoustic probings performed on an IVD-mimicking phantom and six healthy porcine discs demonstrated the ability of these TMM to accurately replicate healthy IVD properties; this could serve as a first step towards an application of photoacoustic imaging to quantifying disc degeneration.
Related Concept Videos
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography