Related Experiment Video
Updated: Jan 13, 2026

Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx
Published on: December 20, 2016
Comprehensive Analysis of Bias in TEMPO NO2 Column Densities Through Pandora Observations
Masoud Ghahremanloo1, Caroline Nowlan1, Gonzalo González Abad1
1Center for Astrophysics | Harvard & Smithsonian, Cambridge, MA, USA.
Abstract:
Tropospheric Emissions: Monitoring of Pollution (TEMPO) is the first geostationary satellite instrument to monitor air pollutants across North America. This study uses Pandora observations to analyze the bias in TEMPO Level-3 total column density of NO2 (TOTNO2) from August 2023 to December 2024. TEMPO achieves high accuracy at 5% cloud-filtering threshold: correlation coefficient (R) of 0.86, index of agreement (IOA) of 0.91, mean absolute bias (MAB) of 1.423 × 1015 molecules/cm2, and a percentage MAB (MABP) of 23.1%, corresponding to a 12% underestimation. Accuracy decreases when pixels with greater cloud-cover are included. Solar zenith angle (SZA) of 10-20° yields the highest accuracy (R: 0.87, MABP: 22.7%), whereas SZAs of 70-80° yield the lowest (R: 0.71, MABP: 35.2%). Consequently, early-morning or near-sunset observations are less reliable than midday. This discrepancy could stem from inaccurate simulation of diurnal variations in the boundary-layer height in the a-priori, and from larger uncertainties in radiative transfer at high SZAs. TEMPO overestimates TOTNO2 at low NO2 levels and underestimates at high levels, with maximum biases of +16% (low) and - 31% (high), respectively. Station-to-station performance varies considerably, with R ranging from 0.29 to 0.84 and MABP from 14.9% to 49.3%. Stations situated at higher altitudes relative to the ground show reduced agreement with TEMPO, as Pandora cannot detect NO2 below the instrument's altitude, whereas TEMPO retrieves the full column. Validation of TEMPO TOTNO2 at TROPOMI overpass time indicates that TEMPO's performance relative to Pandora (IOA: 0.93, MABP: 22.3%) closely matches that of TROPOMI (IOA: 0.92, MABP: 20.1%).
Related Concept Videos
Bias in Epidemiological Studies
Flame Photometry: Overview
Flame Photometry: Lab
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Cluster Sampling Method
To choose a cluster sample, divide the population into clusters (groups) and then randomly select some of the clusters. All the members from these clusters are in the cluster sample. For example, if you randomly sample four departments from your...

