Related Experiment Video
Updated: Jan 13, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Strong-Gradient Diffusion-Weighted Imaging of Prostate Cancer Using an Inside-Out Nonlinear Gradient Coil
Horace Z Zhang1, Nahla M H Elsaid2,3, Terence W Nixon2
1Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA.
Purpose:
To demonstrate improved image quality and lesion conspicuity in prostate diffusion-weighted imaging (DWI) using an inside-out nonlinear gradient coil that provides locally strong gradients (200-500 500 mT/m) at typical prostate positions.
Theory And Methods:
Before applying the nonlinear gradient coil to DWI with Echo Planar Imaging (EPI) readout, we investigated geometric distortion and eddy currents, and proposed necessary corrections. We then developed two DWI protocols (bmax = 1000 and 3000 s/mm2) with minimized echo time (TE) and tested them on volunteers and patients. We validated apparent diffusion coefficient (ADC) maps from the nonlinear gradient acquisition against the reference (linear gradients only). We quantified improvements in signal-to-noise ratio (SNR), lesion contrast-to-noise ratio (CNR), and lesion-to-normal-tissue contrast ratio in the compartmental map of restricted diffusion.
Results:
Corrections effectively reduced nonlinear-gradient DWI artifacts. ADC maps from linear- and nonlinear-gradient-encoded studies agreed well, with a normalized root-mean-square-error of ∼10%, a common level of ADC variation. TE was significantly reduced from 57 to 42-47 ms for moderate b-values (≤ 1000 s/mm2) and from 72 to 42-54 ms for high b-values (≤ 3000 s/mm2). Consequently, SNR increased by 3%-38% (median 16%, p < 0.01) and 7%-38% (median 26%, p < 0.01), respectively. Lesion CNR improved by a median of 133% at b = 2000 s/mm2 and 217% at b = 3000 s/mm2. The restricted diffusion component in lesions was more conspicuous at short TE, with a median 23% increase in lesion-to-normal-tissue contrast ratio (p = 0.02).
Conclusion:
The inside-out nonlinear gradient coil enhances prostate DWI.
More Related Videos
Related Concept Videos
Magnetic Resonance Imaging
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Imaging Studies IV: Magnetic Resonance Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)

