Related Experiment Video
Updated: Jan 13, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Strong-Gradient Diffusion-Weighted Imaging of Prostate Cancer Using an Inside-Out Nonlinear Gradient Coil
Horace Z Zhang1, Nahla M H Elsaid2,3, Terence W Nixon2
1Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA.
A novel nonlinear gradient coil significantly improves prostate diffusion-weighted imaging (DWI) quality. This technology enhances lesion detection and conspicuity in prostate cancer imaging.
Area of Science:
- Magnetic Resonance Imaging
- Medical Physics
- Radiology
Background:
- Prostate diffusion-weighted imaging (DWI) is crucial for detecting prostate cancer.
- Current DWI techniques can be limited by image quality and lesion conspicuity.
- Advanced gradient coil technology may overcome these limitations.
Purpose of the Study:
- To evaluate an inside-out nonlinear gradient coil for enhanced prostate DWI.
- To assess improvements in image quality, lesion conspicuity, and signal-to-noise ratio (SNR).
- To validate apparent diffusion coefficient (ADC) map accuracy.
Main Methods:
- Developed and applied an inside-out nonlinear gradient coil for DWI with Echo Planar Imaging (EPI) readout.
- Investigated and corrected for geometric distortion and eddy currents.
- Acquired DWI data using protocols with bmax=1000 and 3000 s/mm², minimizing echo time (TE).
- Compared nonlinear gradient results with linear gradient acquisitions in volunteers and patients.
Main Results:
- Nonlinear gradient DWI showed reduced artifacts after corrections.
- Apparent diffusion coefficient (ADC) maps demonstrated good agreement between linear and nonlinear gradients.
- Significantly reduced echo time (TE) from 57-72 ms to 42-54 ms.
- Increased signal-to-noise ratio (SNR) by 3%-38% (median 16-26%).
- Improved lesion contrast-to-noise ratio (CNR) by a median of 133-217% and lesion-to-normal-tissue contrast ratio by 23%.
Conclusions:
- The inside-out nonlinear gradient coil significantly enhances prostate DWI quality.
- This technology improves lesion conspicuity and SNR, aiding in prostate cancer detection.
- The method offers a promising advancement for clinical prostate MRI.
More Related Videos
Related Concept Videos
Magnetic Resonance Imaging
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Imaging Studies IV: Magnetic Resonance Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)