Monte Carlo derivation of beam quality correction factors in proton beams: a comparison of Geant4 versions
Guillaume Gabriel Houyoux1, Kilian-Simon Baumann2,3,4,5, Nick Reynaert1
1Radiophysics and MRI Physics Laboratory, Faculty of Medicine, Université Libre de Bruxelles, Brussels, Belgium.
Abstract:
Objective.In the revised version of the TRS-398 Code of Practice (CoP), Monte Carlo (MC) results were added to existing experimental data to derive the recommended beam quality correction factors (kQ) for ionisation chambers in proton beams. While part of these results were obtained from versions v10.3 and v10.4 of the Geant4 simulation tool, this paper demonstrates that the use of a more recent version, such as v11.2, can affect the value of thekQfactors.Approach.The chamber-specific proton contributions (fQ) of thekQfactors were derived for four ionisation chambers using two different versions of the code, namely Geant4-v.10.3 and Geant4-v11.2. A comparison of the total absorbed dose values is performed, as well as the comparison of the dose contribution for primary and secondary particles.Main results.Larger absorbed dose values per incident particle were derived with Geant4-v11.2 compared to Geant4-v10.3 especially for dose-to-air at high proton beam energies between 150 MeV and 250 MeV, leading to deviations in thekQvalues up to 1%. These deviations are mainly due to a change in the physics of secondary helium ions for which the significant deviations between the Geant4 versions is the most stringent within the entrance window or the shell of the ionisation chambers.Significance.Although significant deviations in the MC calculatedfQvalues were observed between the two Geant4 versions, the dominant uncertainty of theWairvalues currently allows to achieve the agreement at thekQlevel. As these values also agree with the current data presented in the TRS-398 CoP, it is not possible at the moment to discriminate between Geant4-v10.3 and Geant4-v11.2, which are therefore both suitable forkQcalculation.
More Related Videos
14:11Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
10:39Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Related Concept Videos
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Maxwell-Boltzmann Distribution: Problem Solving
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...
Beams with Symmetric Loadings
The M/EI...