Optimization of the Contrast Concentration for Low-Tube-Voltage Chest CT: A Randomized Controlled Trial with
Jiho Park1, Bo Mi Gil2, Yun-Hyeon Kim3
1Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, 222, Banpo-daero, Seoul 06591, Republic of Korea.
Abstract:
Objective: To evaluate the effect of low-concentration contrast media (LCCMs) on 100 kVp conventional chest CT by comparing the proportions of acceptable-quality scans obtained using various CM concentrations with those obtained using the standard protocol. Materials and Methods: This prospective, multicenter, randomized controlled trial enrolled adult patients with BMI < 30 who underwent enhanced chest CT between December 2023 and September 2024. Participants were randomly assigned to four groups: one control group (120 kVp, 320 mgI/mL) and three test groups using 100 kVp and standard CM (320 mgI/mL) or LCCMs (270 or 240 mgI/mL). Non-inferiority was tested based on the proportion of acceptable-quality scans independently assessed by two readers. Adverse reactions, including injection site pain and localized and systemic heat sensations, were recorded. Results: A total of 371 participants (mean age: 66.0, IQR: 58-73 years) were randomized. 100 kVp chest CT with LCCM groups showed non-inferior image quality to the standard protocol (270 mgI/mL: reader 1-98.33% confidence interval [CI]: -4.95, 9.37 and reader 2-98.33% CI: -7.11, 7.21; 240 mgI/mL: reader 1-98.33% CI: -6.44, 8.71 and reader 2-98.33% CI: -11.47, 5.11; all p < 0.001). Reader 2 reported a lower proportion of acceptable scans in the 320 mgI/mL low-voltage group (p = 0.11), whereas Reader 1 did not find significant inferiority (p = 0.003). Injection site pain, localized heat, and systemic heat were less frequent in LCCM groups, while systemic heat was only statistically significant (p = 0.003). Conclusions: Low-tube-voltage (100 kVp) chest CECT using LCCMs yields non-inferior image quality compared with the standard protocol while using conventional concentration contrast media under 100 kVp resulted in decreased proportion of diagnostically acceptable scans.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography