Leveraging Central Sleep Apnea Events to Validate the Measurement of Lung Volume Changes Using Thoracic Bio-Impedance
Martine A W Knoops-Borm1,2, Rik Vullings1, Hartmut Schneider2,3,4
1Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands.
Abstract:
Sleep disordered breathing can cause serious health issues, yet current diagnostic methods are cumbersome and prone to error. Thoracic electrical bio-impedance (BioZ) is a promising alternative, but it remains unclear whether the measured BioZ variations reflect lung volume changes. We leverage linear reductions in lung volume during central sleep apnea (CSA) events to assess whether BioZ measurements capture changes in lungs. BioZ signals from 92 sleep studies were analyzed using linear regression to quantify their slope and linearity (R2). Group differences were assessed, and a linear mixed-effects model was used to evaluate the impact of the body mass index (BMI), gender, and sleeping position. Welch's ANOVA showed significant differences between CSA and breathing segments. A chi-squared analysis showed that CSA events were more likely to exhibit negative slopes. The mixed-effects model found no BMI or gender effects, but the supine posture was significantly associated with more negative linear trends. These findings indicate that BioZ captures lung volume changes and that the sleeping position significantly modulates how clearly these changes appear in the signal.
More Related Videos
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Sleep Apnea
The condition is more prevalent among...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes and Capacities I
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: