The KUYUY Accelerograph and SIPA System: Towards Low-Cost, Real-Time Intelligent Seismic Monitoring in Peru
Carmen Ortiz1,2, Jorge Alva1, Roberto Raucana1
1Research Center for Digital Transformation in Engineering, Universidad Nacional de Ingeniería, Lima 15333, Peru.
Abstract:
Accelerographs are essential instruments for quantifying strong ground motion, serving as the foundation of modern earthquake engineering. In Peru, the first accelerographic station was installed in Lima in 1944; since then, various institutions have promoted the expansion of the national network. However, this network's spatial coverage and instrumentation remain insufficient to properly characterize strong motion and support seismic risk reduction policies. In this context, the KUYUY accelerograph is presented as a low-cost, low-noise device equipped with real-time telemetry and high-performance MEMS sensors. Its interoperability with the Intelligent Automatic Processing System (SIPA) enables real-time monitoring and automated signal analysis for seismic microzonation studies and rapid damage assessment, contributing to seismic risk reduction in Peru. The validation process included static gravity calibration, field comparison with a reference accelerograph, and an initial deployment in Lima and Yurimaguas. The results demonstrate the proposed accelerograph's linear response, temporal stability, and amplitude consistency with respect to high-end instruments, with differences below 5-10%.
More Related Videos
08:57VacuSIP, an Improved InEx Method for In Situ Measurement of Particulate and Dissolved Compounds Processed by Active Suspension Feeders
Published on: August 3, 2016
09:35Measurement of the Hand Transmitted Vibration of the Human Hand Arm System During Operation of a Hand Tractor
Published on: June 16, 2021
Related Concept Videos
Pulse Assessment Sites
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...