Related Experiment Video
Updated: Jan 13, 2026

Author Spotlight: A Stable Phantom Material for Optical and Acoustic Imaging
Published on: June 16, 2023
Combined Use of Vibrational Spectroscopy, Ultrasonic Echography, and Numerical Simulations for the Non-Destructive
Dimitra Apostolidou1, Afrodite Tryfon1, Dionysios E Mouzakis2
1Physical Chemistry Laboratory, Department of Chemistry, University of Ioannina, 45110 Ioannina, Greece.
Abstract:
This paper describes how the thermal treatment of 3D-printed PLA samples, fabricated by Fused Deposition Modeling (FDM), affects elastic properties by means of vibrational spectroscopy and ultrasonic echography. Longitudinal and shear sound velocities were measured experimentally to determine Young's, bulk, shear, and longitudinal moduli, as well as Poisson's ratio. The results were complemented with two different simulation approaches-the elastodynamic finite integration technique (EFIT) and the equivalent electric analog technique implemented with LPSpice-whose predictive performance was assessed using statistical performance metrics. The circuit-based simulation method demonstrated superior agreement with experimental behavior compared to EFIT. Both measured and simulated data reveal that PLA chains undergo overall structural strengthening and enhanced packing up to 2 h of heating, followed by a clear reduction in these enhancements as thermal degradation emerges with further heating. Poisson's ratio remained relatively stable throughout, indicating minimal impact on strain distribution characteristics despite observable stiffening and subsequent softening. Vibrational ATR (Attenuated Total Reflection) spectra corroborated these findings through systemic shifts in C-COO, C-O-C, and C-O stretching modes associated with the same structural modifications. Overall, this combined experimental-simulation framework provides an integrated understanding of thermally induced mechanical and molecular evolution in 3D-printed PLA relevant to defense applications.