A Pilot Human Study on Dual Photoplethysmography for Continuously Monitoring Pulse Wave Velocity and Blood Pressure
Tien Nguyen1, Sai Satvik Kolla1, Henry Wang1
1Bristol Medical School (PHS).
None:
Hypertension is a leading contributor to cardiovascular disease, stroke, and chronic kidney disease worldwide. However, current blood pressure (BP) monitoring techniques, whether auscultatory, oscillometric, or invasive, are constrained by episodic measurement, user variability, and limited feasibility for real-world, continuous monitoring. These limitations hinder early detection of abnormal BP patterns and long-term cardiovascular risk assessment. This paper presents a noninvasive device based on photoplethysmography (PPG) signals, with calculated Pulse Wave Velocity (PWV), that combines off-the-shelf sensors with an infrared-based dual PPG sensor. The device combines PPG signals and physiological measurements to predict blood pressure comprehensively using machine learning, with initial trials on 25 participants demonstrating promising accuracy with mean differences of 1.1 mmHg for Systolic Blood Pressure (SBP), -0.9 mmHg for Diastolic Blood Pressure (DBP), and -0.2 mmHg for Mean Arterial Pressure (MAP) compared to standard measurements with the Vicorder device. While primarily tested on a young population, the device shows potential for continuous, real-world BP and PWV monitoring, offering greater usability and accessibility than traditional tonometry- and oscillometry-based devices.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: