Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
The Impact of CT Reconstruction Parameters on Emphysema Index Quantification, HU-Based Measurements, and Goddard
Rahma Saad Mohamed1, Ahmed Sayed Abd El Bassset2, Ahmed A G El-Shahawy3
1Department of Radiology & Medical Imaging Technology, Faculty of Applied Health Sciences Technology (AHST), Beni-Suef University, Beni-Suef, Egypt, bsu.edu.eg.
Background:
Quantitative computed tomography (CT) plays a crucial role in assessing emphysema severity in chronic obstructive pulmonary disease (COPD). However, variations in CT reconstruction parameters-slice thickness (ST), kernel selection, field of view (FOV), and reconstruction gaps-can affect emphysema index (EI) quantification, impacting diagnostic accuracy and study comparability.
Objective:
This study examines how CT reconstruction parameters influence EI quantification using Hounsfield Unit (HU)-based measurements and the Goddard Score (GS) to refine imaging protocols for emphysema assessment.
Methods:
Low-dose CT scans were performed on 31 subjects, with images reconstructed using ST (0.6-10 mm), kernel settings (Br and Hr series), FOV ranges (250-370 mm), and reconstruction gaps (0.25-3 mm). EI was defined as the percentage of lung volume with attenuation values below - 950 HU, while GS provided a semi-quantitative assessment of emphysema severity. Statistical analyses evaluated the effects of reconstruction parameters on EI and GS.
Results:
Variations in FOV, kernel selection, and reconstruction gaps had negligible effects on the GS (p > 0.05), suggesting that these parameters do not introduce structural distortions in pulmonary imaging. However, ultra-thin slices (0.6 mm) enhanced the detection of subtle emphysematous changes, slightly increasing GS, though higher image noise may affect interpretation. Additionally, ST significantly influenced EI values due to partial volume effects, with thinner slices yielding lower attenuation values.
Conclusion:
These findings confirm the reliability of CT-based emphysema quantification and highlight the importance of optimizing ST to balance sensitivity and image clarity. Standardized imaging protocols and AI-driven texture analysis could further enhance quantitative emphysema assessment, improving disease monitoring and therapeutic decision-making in COPD management.