Feasibility of Echocardiography-guided Percutaneous Transapical Lead Implantation for Intraventricular Septal Pacing:
Zhaohui Qiu1, Xianhao Wu1, Haiyan Chen2
1Department of Cardiology, Shanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine Shanghai, China.
Background:
Transvenous lead implantation often faces challenges regarding venous access and lead-related complications. This study evaluated the feasibility and safety of a novel echocardiography-guided percutaneous transapical intraventricular septum (PTAIVS) pacing approach in an animal model.
Methods:
Twelve adult dogs underwent PTAIVS lead implantation guided by transthoracic and transoesophageal echocardiography. Leads were introduced percutaneously through the apex and fixed in the mid-to-basal septum. The first six dogs were implanted with a pacing set with a coaxial introducer needle (CareFusion) and a Model 3830 lead (Medtronic), whereas an improved pacing set with an extended helix lead was used in the next six dogs. The first three dogs were used for evaluation of acute gross pathology, with the remaining nine followed up over a period of 4-12 weeks. Pathological examinations were performed at the end of the follow-up period.
Results:
Successful lead placement without procedural complications was achieved in all dogs, with a mean (± SD) procedural time of 28.8 ± 4.8 min. At implantation, the median (interquartile range) capture threshold was 1.7 (0.85-2.50) V, the R-wave amplitude was 6.80 (6.13-13.00) mV and impedance was 536 (510-922) Ω. In the initial six dogs in which the unmodified pacing system was used, lead dislodgement occurred at the 1-month follow-up. Modifications to the system eliminated dislodgement at 1 month, but varying degrees of displacement were observed by 3 months.
Conclusion:
This study demonstrates the initial technical feasibility of echocardiography-guided PTAIVS pacing, offering a potential alternative to traditional transvenous methods. However, further refinements are essential to improve long-term lead stability.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection