In silico study of a bilayer titanium dental implant with a porous titanium and hydroxyapatite composite outer layer
Vamsi Krishna Dommeti1, Francesco Valente2,3, Cristina Falcinelli4
1Department of Mechanical Engineering, College of Engineering and Technology, Faculty of Engineering and Technology, SRM Institute of Science and Technology, Kattankulathur, Kanchipuram, Chennai, Tamil Nadu, India.
Abstract:
This study aims to develop an innovative bilayered dental implant design featuring a titanium alloy core with a porous composite titanium (Ti) and hydroxyapatite (HA) outer layer to enhance implant stability and patient outcomes. Using SolidWorks 2017, 3D models of the implants and a mandibular bone segment were created. A Finite Element (FE) analysis was then conducted with ANSYS Workbench to assess the mechanical behavior under a 250 N axial compressive load, comparing the bilayered implant to a conventional titanium implant. Variables like porosity (ranging from 10 to 90% in 10% increments), HA content (ranging from 10 to 50% in 5% intervals), and outer layer thickness (2 mm, 1.5 mm and 1 mm) were systematically analyzed. Each configuration was evaluated based on von Mises stress distribution and interfacial strain in peri-implant bone. Results indicated that all porous designs of bilayered implants had significantly lower von Mises stress than traditional implant, with reductions ranging from approximately 69 to 94%, depending on HA/Ti composition and shell thickness. The non-porous bilayer configurations also showed clear stress reductions, with decreases from approximately 72 to 90%, depending on the HA/Ti composition and shell thickness. However, these reductions were slightly lower than those observed in porous designs, with maximal reductions occurring in the porous core of some 2 mm bilayered implant configurations. The combined evaluation of strain and von Mises stress analyses identified the 2 mm core diameter with a 2 mm porous shell as the optimal design, providing favorable microstrain, improved load transfer, and reduced stress concentrations. This modification promotes a more favorable mechanical interaction between the implant and surrounding bone. These findings underscore the potential of bilayered porous implants to improve stability and bone integration, marking a significant step forward in dental implant technology. Further research, including experimental validation, is encouraged to verify these results and investigate other loading conditions, promoting the development of more effective and sustainable dental implant solutions.
More Related Videos
Related Concept Videos
Bone Remodeling
The Bone Matrix
Bone Remodeling and Repair