Application of radiomics-based image filtering to improve deformable image registration accuracy in thoracic images
Yoshiro Ieko1, Noriyuki Kadoya2, Hisanori Ariga1
1Department of Radiation Oncology, Iwate Medical University School of Medicine, Yahaba, Japan.
Background And Purpose:
Deformable image registration (DIR) is an important technique in radiation therapy. To improve DIR accuracy, we applied radiomics-based image filtering as a preprocessing step before DIR.
Materials And Methods:
Thoracic four-dimensional computed tomography (CT) images of 10 patients with lung or esophageal cancer were examined. Peak-inhale and peak-exhale images were used for DIR. Before DIR, these images were converted into 90-voxel-based radiomics-based filtered images using extracted local radiomics features, respectively. On each filtered image, DIR between the peak-inhale and peak-exhale filtered images was performed. After DIR, the peak-inhale CT images were deformed to peak-exhale CT images using the displacement vector fields obtained from the DIR. The registration errors obtained from each radiomics-based DIR were calculated using landmark pairs and compared with conventional CT-based DIR using the same DIR parameters.
Results:
In radiomics-based DIR, the lowest registration errors (95th percentile) for intensity and texture features were 0.96 mm (right-left), 1.35-1.38 mm (anterior-posterior), 2.04-2.13 mm (superior-inferior), and 2.49-2.57 mm (three-dimensional). For CT-based DIR, the corresponding registration errors were 1.31 mm, 1.72 mm, 3.45 mm, and 3.98 mm.
Conclusions:
By applying radiomics-based image filtering before DIR as a preprocessing, the registration error was lower than that of conventional CT-based DIR, suggesting that using radiomics may improve the accuracy of DIR.