Related Experiment Video
Updated: Aug 8, 2026

A Bedside, Single Burr Hole Approach to Multimodality Monitoring in Severe Brain Injury
Published on: March 26, 2019
Safety and effectiveness of bolt-mounted versus tunnelled external ventricular drains: A systematic review,
Shaan Patel1, Shiva A Nischal2, Ayush Sinha2
1Department of Neurological Surgery, Thomas Jefferson University Hospital, Philadelphia, PA 19107, USA.
Background:
External ventricular drains (EVDs) are fundamental to neurocritical care, yet substantial procedural heterogeneity persists, particularly regarding bolt-mounted versus tunnelled catheter fixation. The relative safety and effectiveness of these approaches remain unclear, with conflicting data from observational studies and a lack of trial-level evidence.
Objective:
To compare bolt-mounted and tunnelled EVDs across accuracy, reoperation, and key safety outcomes using systematic review, meta-analysis, and trial-sequential analysis.
Methods:
Following PRISMA guidelines, PubMed, Embase, and CENTRAL databases were searched (November 2025) for randomised or observational studies comparing bolt-mounted with tunnelled EVDs in adults. Two reviewers independently screened studies, extracted data, and assessed risk of bias. Primary outcomes were optimal catheter placement (Kakarla Grade I) and reoperation for EVD-related complications. Secondary outcomes included iatrogenic intracranial haemorrhage (ICH), cerebrospinal fluid (CSF) infection, CSF leak, catheter obstruction or malfunction, accidental discontinuation, and drainage duration. Random-effects meta-analyses were conducted using restricted maximum likelihood estimation. Heterogeneity was quantified, and certainty of evidence was assessed using GRADE. Trial-sequential analysis was performed for reoperation to determine whether available data met required information size thresholds.
Results:
Ten studies encompassing 2008 patients (800 bolt-mounted, 1208 tunnelled) were included. Bolt-mounted EVDs demonstrated significantly higher optimal catheter accuracy (RR 1.27; 95% CI: 1.06-1.51; P < 0.01; I2 = 29.6 %). Reoperation was numerically lower with bolt-mounted systems (RR 0.51; 95% CI: 0.22-1.36; P = 0.19; I2 = 85 %), although trial-sequential analysis showed the cumulative Z-curve crossed the monitoring boundary without reaching the required information size, indicating insufficient evidence for definitive inference. Bolt-mounted EVDs were associated with lower CSF leak risk (RR 0.13; 95% CI: 0.04-0.47; P < 0.01) and reduced catheter obstruction (RR 0.46; 95% CI: 0.25-0.83; P < 0.05). No significant differences were observed in iatrogenic ICH (RR 1.23; 95% CI: 0.54-2.81; P = 0.62), CSF infection (RR 0.88; 95% CI: 0.71-1.09; P = 0.23), accidental discontinuation (RR 0.41; 95% CI: 0.11-1.59; P = 0.20), or drainage duration (MD 0.56 days; 95% CI = -1.02-2.13; P = 0.49).
Conclusions:
Bolt-mounted EVDs were associated with higher catheter accuracy, reduced CSF leak, and improved mechanical reliability without increased infection or haemorrhage. Although reoperation may be lower with bolt-mounted systems, current evidence remains underpowered for firm conclusions. These findings challenge historical assumptions regarding tunnelled catheters and may inform context-specific device selection in contemporary neurocritical care.
More Related Videos
Related Concept Videos
Cavity Drainage and Flashings in Masonry walls
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Quality of Water
Testing Water Quality
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are known. The...
Multiple Pipe Systems
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...
Design Example: Analyzing Capacity Contours for Flood Risk Assessment