Related Experiment Video
Updated: Jan 17, 2026

Guidelines for Elective Pediatric Fiberoptic Intubation
Published on: January 17, 2011
Emergency bedside fibreoptic bronchoscopy for mucus plug-related dynamic airway obstruction causing extreme
Saurabh Trivedi1, Pooja Thaware1, Jitendra Kushwaha1
1Trauma & Emergency Medicine, All India Institute of Medical Sciences Bhopal, Bhopal, India.
A woman in her 20s with tracheal stenosis following corrosive acid ingestion presented to the emergency department (ED) with acute respiratory failure 5 months after the initial injury, despite having a tracheostomy in situ. She had extreme hypercapnia (pCO2 198 mm Hg, pH 6.8) that persisted despite tracheostomy tube change and mechanical ventilation. Bedside flexible fibreoptic bronchoscopy revealed severe distal tracheal stenosis complicated by an adherent mucus plug creating a dynamic ball-valve obstruction. Ventilation improved only after clearance using an ultraslim 3.1 mm neonatal fibreoptic bronchoscope, with rapid normalisation of gas exchange within hours. This case highlights that dynamic mucus impaction in post-corrosive tracheal stenosis can cause immediately life-threatening but potentially reversible extreme hypercapnia and underscores the need for EDs managing complex airways to maintain ready access to paediatric and neonatal ultra-slim fibreoptic bronchoscopes.
A woman in her 20s with tracheal stenosis following corrosive acid ingestion presented to the emergency department (ED) with acute respiratory failure 5 months after the initial injury, despite having a tracheostomy in situ. She had extreme hypercapnia (pCO2 198 mm Hg, pH 6.8) that persisted despite tracheostomy tube change and mechanical ventilation. Bedside flexible fibreoptic bronchoscopy revealed severe distal tracheal stenosis complicated by an adherent mucus plug creating a dynamic ball-valve obstruction. Ventilation improved only after clearance using an ultraslim 3.1 mm neonatal fibreoptic bronchoscope, with rapid normalisation of gas exchange within hours. This case highlights that dynamic mucus impaction in post-corrosive tracheal stenosis can cause immediately life-threatening but potentially reversible extreme hypercapnia and underscores the need for EDs managing complex airways to maintain ready access to paediatric and neonatal ultra-slim fibreoptic bronchoscopes.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Acute Respiratory Failure-III
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...

