Sustained response to minimal-dose tagraxofusp in a patient with BPDCN and advanced chronic kidney disease
Christina Brummer1, Katja Evert2, Felix Keil2
1Department of Hematology and Oncology, University Hospital of Regensburg, Regensburg, Germany. christina.brummer@ukr.de.
Abstract:
Blastic plasmacytoid dendritic cell neoplasm (BPDCN) is an extremely rare hematologic malignancy with an aggressive course and poor prognosis. Treatment remains challenging particularly in patients who are ineligible for stem cell transplantation due to resistance to conventional chemotherapy. The introduction of tagraxofusp, a CD123-directed cytotoxin, has significantly expanded therapeutic options and improved outcomes for patients with BPDCN. However, its use can be accompanied by notable adverse events, especially capillary leak syndrome, underscoring the need for careful patient selection and monitoring. Up to date, no data is available regarding the safety of tagraxofusp in patients with chronic kidney failure and cardiovascular co-morbidities. We present the case of a 79-year-old male who developed a solitary, rapidly progressing skin lesion on his lower back. The lesion represented the first manifestation of BPDCN with bone marrow infiltration and concomitant myelodysplastic syndrome (MDS). Molecular analysis identified mutations in CBL, TET2, ZRSR2 and KRAS. Non-eligible for stem cell transplantation, the patient was admitted to treatment with tagraxofusp in a dose-reduced protocol due to concomitant chronic kidney disease (CKD). After three doses of the first cycle, treatment needed to be stopped due to acute-on-chronic renal failure. After treatment disruption, kidney failure was completely restituted to pre-treatment levels. Notably, skin and bone marrow biopsies demonstrated a dermatologic complete response and partial remission of bone marrow infiltration. A watch and wait concept was followed, and prolonged therapy response was obtained for 8 months before relapse. To our knowledge, this is the first reported case demonstrating the use of tagraxofusp in a patient with BPDCN and advanced chronic kidney disease, showing that even a minimum of tolerated treatment dose can induce a sustained response. Despite the risk of adverse events, tagraxofusp should be considered a viable treatment option for elderly patients with poor performance status and significant comorbidities who are ineligible for intensive chemotherapy or stem cell transplantation, as even limited exposure may achieve meaningful clinical responses.
More Related Videos
08:505/6th Nephrectomy in Combination with High Salt Diet and Nitric Oxide Synthase Inhibition to Induce Chronic Kidney Disease in the Lewis Rat
Published on: July 3, 2013
08:46Implementing Patch Clamp and Live Fluorescence Microscopy to Monitor Functional Properties of Freshly Isolated PKD Epithelium
Published on: September 1, 2015
Related Concept Videos
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Chronic Kidney Disease II: Clinical Manifestations
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Chronic Kidney Disease III: Interprofessional Care