Post-Wildfire Indoor Pollution in WUI Areas following the 2025 Los Angeles Fires. Part I. Establishing Baseline
Ehsan Goftari1,2, Jose Rivera Carias1, London Fulford1
1Department of Civil, Construction, and Environmental Engineering, San Diego State University, San Diego, California 92182, United States.
Abstract:
Wildland-urban interface (WUI) fires pose unique environmental pollution challenges due to the combustion of both natural vegetation and synthetic building materials. Following the 2025 Palisades and Eaton wildfires in Los Angeles, we conducted a field study to characterize indoor air quality and surface contamination in 19 homes before reoccupancy. Indoor PM2.5 and PM10 concentrations averaged 3.45 and 31.66 μg/m3, respectively, with several homes showing indoor-to-outdoor (I/O) ratios of >1 (particularly for PM10) compared to typical I/O values of 0.45-0.8 in residences, indicating persistent indoor particle reservoirs. Depending on the air-exchange rate, elevated indoor PM levels in noncleaned homes may arise from two contrasting mechanisms: low ventilation that traps resuspended fire residues triggered by movements during sampling and high ventilation that induces turbulence and disturbs heavily contaminated entry zones. Regression analysis suggested that proximity to the fire, absence of air purifiers, use of non-HEPA vacuums, and open windows during the fire significantly increased indoor PM levels, explaining 73% (PM10) and 86% (PM2.5) of the variation across homes. Airborne metal concentrations were below health-based thresholds; however, surface wipe samples revealed widespread contamination, with potassium, magnesium, aluminum, and iron frequently exceeding 1000 μg/ft2, and detectable levels of zinc, copper, and manganese in many homes. Lead concentrations exceeded the EPA's dust clearance levels in multiple homes, especially on window sills and entry floors. Our findings highlight that while airborne risks may subside within weeks after the fire, indoor surfaces can retain fire-related pollutants, presenting ongoing exposure risks even 2 months after the fire.
More Related Videos
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
05:18Measuring Carbon Content in Airway Macrophages Exposed to Carbon-Containing Particulate Matters
Published on: July 12, 2024
Related Concept Videos
Efflorescence in Masonry
While initial efflorescence is common post-construction and can be cleaned with water and a brush, in certain instances, efflorescence can reappear and gradually diminish over time as salts are leached out...
Deleterious Substances in Aggregate
Another type of impurity is clay and fine material that...
Waterproofing and Anti-Bacterial Admixtures in Concrete
Waterproofing admixtures render concrete hydrophobic,...
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground cistern.
Microbial Bioremediation of Uranium