Related Experiment Video
Updated: Jul 24, 2026

Fabrication of Electrochemical-DNA Biosensors for the Reagentless Detection of Nucleic Acids, Proteins and Small Molecules
Published on: June 1, 2011
Pristine paper-based device for non-enzymatic electrochemical detection of creatinine: sensitization via electrode
1Department of Chemistry, RV Institute of Technology and Management, Chaithanya Layout, J. P. Nagar, Bengaluru-560076, Visvesvaraya Technological University, Belagavi, 590018, India.
Abstract:
Herein, we report a non-enzymatic paper-based device for selective electrochemical detection of creatinine. This work demonstrates three modification strategies adopted for the paper-based electrochemical sensing device (PESD) for the detection of creatinine. Copper, a non-enzymatic metal electrode, was fabricated on the Whatman paper without sophisticated instrumentation. The fabricated pristine non-enzymatic PESD could detect creatinine in the linear range 10 µM to 90 µM with a detection limit of 6.6 µM. Further, the electrode and Whatman paper were modified with silver to improve the sensitivity of PESD towards creatinine. Firstly, the working electrodes were modified by the Scotch tape strategy via galvanic displacement of Ag on Cu. The Ag-modified Cu electrodes were stuck on the Whatman paper, which sensitized the creatinine in the linear range 10 nM to 240 nM with a detection limit of 0.089 nM. Secondly, the Whatman paper was modified by mussel-inspired soak, polymerize, and then reduction of silver on the paper. The modified paper works similarly to the modified electrode with Ag in the linear range 10 nM to 90 nM with a detection limit of 2.5 nM. Further, the fabricated pristine PESD was tested for Jaffe's inspired indirect electrochemical detection of creatinine in the linear range 10 µM to 100 µM with a detection limit of 6.4 µM. The sensitivity of the fabricated pristine PESD was improved from µM to nM by adopting modification strategies. The reported PESD with the least interference from the co-existing biomolecules has the potential applicability of monitoring creatinine in urine sample analysis.
More Related Videos
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
03:58Author Spotlight: Revolutionizing Microfluidics Through Microchannel Fabrication on Nanopaper
Published on: October 6, 2023
Related Concept Videos
Potentiometry: Membrane Electrodes
Amperometry: Overview
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...