Fluoroscopy Time and Radiation Exposure in TEVAR Versus EVAR: A Systematic Review and Meta-Analysis
Fotios O Efthymiou1, Christos F Pitros2, Constantine N Antonopoulos2
1Department of Medical Physics, School of Medicine, University of Patras, Patras, Greece.
This study found thoracic endovascular aneurysm repair (TEVAR) uses less fluoroscopy time (FT) than endovascular aneurysm repair (EVAR). However, radiation doses like kerma-area product (KAP) were similar, highlighting complex radiation exposure factors in endovascular procedures.
Area of Science:
- Medical Imaging
- Interventional Cardiology
- Radiation Oncology
Background:
- Ionizing radiation is a known risk in endovascular surgery.
- Patient radiation exposure varies significantly between different endovascular procedures.
Purpose of the Study:
- To systematically review and meta-analyze patient radiation exposure during endovascular aneurysm repair (EVAR) and thoracic EVAR (TEVAR).
- To compare fluoroscopy time (FT), kerma-area product (KAP), and cumulative air kerma (CAK) between EVAR and TEVAR.
Main Methods:
- A PRISMA-compliant literature search was conducted across major databases (MEDLINE, Scopus, Cochrane Library) from June 2015 to June 2025.
- Seventy-eight studies (73 EVAR, 5 TEVAR) with ≥20 patients were included, reporting FT, KAP, or CAK.
- Random-effects modeling was used for pooled analysis, with risk-of-bias and publication bias assessed.
Main Results:
- TEVAR showed significantly shorter FT (15.25 min) compared to EVAR (28.50 min) (p<0.001).
- No significant differences were found in KAP (151.08 vs. 147.46 Gycm²; p=0.970) or CAK (804.92 vs. 1091.03 mGy; p=0.090).
- High heterogeneity (I²>85%) was observed; only 11.5% of studies reported ALARA compliance, and fusion imaging was used infrequently (9%).
Conclusions:
- Radiation exposure during EVAR and TEVAR is variable, influenced by anatomy, technology, and practice.
- While TEVAR has shorter FT, its KAP values are comparable or higher than EVAR, potentially due to thoracic imaging geometry.
- Limited data for TEVAR restrict definitive comparative conclusions.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation I: X-ray and CT
Hazard Ratio
For example, in a clinical trial...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Biological Effects of Radiation