Related Experiment Video
Updated: May 2, 2026

Stem Cell Transplantation Strategies for the Restoration of Cognitive Dysfunction Caused by Cranial Radiotherapy
Published on: October 18, 2011
Accuracy of reirradiation dose constraints for the mandible and carotids
Sara Bornedal1, Jeehong Lee1, Tim Melhus1
1Department of Nuclear Medicine and Medical Physics, Karolinska University Hospital, Stockholm, Sweden.
Abstract:
When reirradiation dose constraints are derived using accumulated dose, the underlying image registrations contribute to the uncertainty. We performed a structure-based evaluation of deformable image registrations, to estimate the uncertainty in previously published dose constraints related to carotid blowout and osteoradionecrosis after head and neck reirradiation. With the workflow of the current analysis, the uncertainty was small in the majority of the cases (<4 Gy in accumulated equivalent dose in 2-Gy fractions), but with substantial outliers resulting from anatomical alterations. Our previously suggested dose constraints appear to be reliable with regard to the underlying image registrations.