Related Experiment Video
Updated: Jul 13, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Surface Quality of Direct Composite Resin Restorations Fabricated Using Different Resin Injection Guides
Purpose:
To evaluate the impact of different resin injection guides (RIGs) on the surface roughness (Ra), microhardness (MH), and conversion degree (CD) of direct composite resin restorations.
Materials And Methods:
Disc-shaped specimens (diameter: 4.5 mm, thickness: 2 mm) were fabricated using five molding methods (n = 16 per group): freehand filling (FH), transparent polyester strip (PS), transparent polyvinyl siloxane guide (PVS), flexible resin guide with rigid shell (FR), and rigid resin guide (RG). Surface topography was analyzed using a multi-functional tribometer, and Ra values were calculated. MH was measured with a microhardness tester. CD was determined via Fourier transform infrared spectroscopy. Data were analyzed with ANOVA and post hoc tests.
Results:
Significant differences in Ra were found (P < .05), in the order of PS < FH < PVS < FR < RG. The PS, FR, and RG groups showed no significant differences in MH or CD (P > .05), but these values were significantly greater than those in the FH and PVS groups (P < .05). The PVS group had higher MH and CD than the FH group (P < .05).
Conclusions:
The use of guides prevents formation of the oxygen inhibition layer, increasing MH and CD by up to 22% compared to the freehand technique. Although all guides increased Ra compared to the polyester strip, the PVS guide produced the smoothest surfaces among the RIGs, albeit with lower MH and CD than the 3D-printed guides (FR, RG).
Related Concept Videos
Accelerators
The effectiveness of calcium chloride can...
Retarders
The function of retarders is to delay the setting of concrete, and this effect can be measured using a penetration test. The retardation process involves adding...