Related Experiment Video
Updated: Jan 20, 2026

Porcine As a Training Module for Head and Neck Microvascular Reconstruction
Published on: September 29, 2018
Quality of Head and Neck Diffusion-weighted MR Imaging Using a Combination of the Periodically Rotated Overlapping
Taro Fujiwara1, Noriyuki Fujima2, Hiroyuki Hamaguchi1
1Department of Radiological Technology, Hokkaido University Hospital, Sapporo Hokkaido, Japan.
Purpose:
To evaluate whether periodically rotated overlapping parallel lines with enhanced reconstruction-diffusion-weighted imaging (PROPELLER-DWI) combined with deep learning-based reconstruction (DLR) improves head and neck DWI, we conducted a primary comparison of PROPELLER-DWI with DLR at varying strengths and without DLR, and a secondary comparison of DLR-processed PROPELLER-DWI with DLR-processed single-shot echo-planar imaging (EPI)-DWI.
Methods:
Ten healthy adults (8 males, 2 females) participated in the study. PROPELLER-DWI and single-shot EPI-DWI images were acquired using a 3-Tesla MRI system (Discovery MR750w; GE Healthcare, Waukesha, WI, USA) with various recon deep-learning strength (DLS) values: off (DLS-Off), low (DLS-L), medium (DLS-M), and high (DLS-H). We measured the SNR and contrast ratio on DWI images and value of coefficient of variation (CV) on apparent diffusion coefficient (ADC) maps for a quantitative evaluation. For a qualitative evaluation, we visually evaluated the overall image quality, degree of geometric distortion, and magnetic susceptibility artifacts.
Results:
The SNRs for PROPELLER and EPI-DWI improved with the increase in the DLS level, with DLS-H showing a significantly higher SNR than DLS-Off. ADC maps demonstrated lower CVs at higher DLS levels, significantly lower in DLS-H than DLS-Off. The qualitative evaluation revealed that PROPELLER-DWI with DLR (at all DLS levels: -L, -M, and -H) provided significantly better overall image quality than that without DLR. In addition, PROPELLER-DWI demonstrated significantly higher qualitative scores across all evaluation items (i.e., overall image quality, geometric distortion, and magnetic susceptibility artifacts) compared with EPI-DWI.
Conclusion:
In head and neck DWI, PROPELLER-based acquisition with DLR enabled the acquisition of visually superior image quality. This approach is clinically useful for the head and neck radiology.
More Related Videos
05:07Author Spotlight: Implementing the Enhanced Recovery After Surgery Concept in Rehabilitation Following Anterior Cruciate Ligament Reconstruction
Published on: March 1, 2024
08:00Imaging and 3D Reconstruction of Cerebrovascular Structures in Embryonic Zebrafish
Published on: April 22, 2014
Related Concept Videos
07:43Porcine As a Training Module for Head and Neck Microvascular Reconstruction
05:07Early Weight-Bearing Rehabilitation Protocol After Anterior Cruciate Ligament Reconstruction
08:00Imaging and 3D Reconstruction of Cerebrovascular Structures in Embryonic Zebrafish
08:01Designing CAD/CAM Surgical Guides for Maxillary Reconstruction Using an In-house Approach
07:29Deep Vascular Imaging in the Eye with Flow-Enhanced Ultrasound
08:18Three-Dimensional Reconstruction of Orbital Fractures