Related Experiment Video
Updated: Jan 20, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Intramedullary nail design for Thais with novel multi-femur shape optimization approach
Duangkamon Sayabut1,2, Chanyaphan Virulsri3,4,5, Pairat Tangpornprasert1,2,6
1Center of Excellence for Prosthetic and Orthopedic Implant, Chulalongkorn University, Bangkok, 10330, Thailand.
None:
Femoral fractures, often resulting from high-energy accidents, are commonly treated with intramedullary nails. Most currently used intramedullary nails are designed based on the anatomical characteristics of the Caucasian population, which are unsuitable for Asian populations due to differences in femoral medullary canal curvature. This mismatch causes stress in the femur, which leads to nail tip penetration. This research proposes a novel multi-femur shape optimization approach to design a long intramedullary nail that reduces stress on the femur by better conforming to the Thai femoral medullary canal. 60 CT scan images of Thai femurs were analyzed, and ten representative femurs were selected to cover the geometric diversity of the femur population using k-means clustering. The nail curve was modeled using four circular arcs, with radii optimized within a 700-1200 mm boundary. The nails were simultaneously optimized in the ten representative femurs utilizing a multi-objective genetic algorithm (MOGA) in Ansys, with the objective of minimizing the maximum principal stress in all ten femurs. The multi-femur shape optimized nail can reduce stresses in the representative femurs. Finite element analysis was conducted to compare the stresses induced by the multi-femur shape optimized nail with the stress caused by the commercial nails with radii of 1275 mm, 1500 mm, and 2000 mm. The results indicate that the multi-femur shape optimized nail significantly reduced the average maximum principal stress in randomly selected femurs. This research demonstrates that a multi-femur shape optimization approach can effectively design an intramedullary nail that reduces stress in a diverse set of femurs, making it a better fit for the Thai femur population. The optimized nail design was further evaluated in a verification model, including lag/distal screws and a one-leg-stance load; the stress in the multi-femur shape optimized nail was substantially lower than the commercial designs.
Related Concept Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
05:43Protocol for Developing a Femur Osteotomy Model in Wistar Albino Rats
06:59Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents
05:46Establishing a Diaphyseal Femur Fracture Model in Mice
14:23Design and Optimization Strategies of a High-Performance Vented Box