Related Experiment Video
Updated: Jan 20, 2026

Biological Samples Preparation for Speciation at Cryogenic Temperature using High-Resolution X-Ray Absorption Spectroscopy
Published on: May 27, 2022
Boltzmann Thermometry at Cryogenic Temperatures Exploiting Stark Sublevels in Er3+/Yb3+-Codoped Yttrium Oxide
Thomas Possmayer1, Allison R Pessoa2,3, Jefferson A O Galindo3
1Chair in Hybrid Nanosystems, Faculty of Physics, Ludwig-Maximilians-Universität München, 80539 München, Germany.
None:
The development of reliable luminescent nanothermometers for cryogenic applications is essential for advancing quantum technologies, superconducting systems, and other fields that require precise, high-spatial-resolution temperature monitoring. Lanthanide-doped systems are vastly employed to this purpose, and typically perform optimally at or above room temperature when manifold-to-manifold transitions are used. In this work we exploit individual Stark sublevels to demonstrate an optical Boltzmann thermometer based on Er3+/Yb3+ codoped yttria (Y2O3) nanoparticles that operates effectively across the temperature range from 25 to 175 K. This is achieved due to the pronounced crystal field environment of the Y2O3 host matrix, leading to well-separated Stark lines in the luminescence spectrum of the Er3+ ions. By applying the Luminescence Intensity Ratio (LIR) method to transitions originating from two Stark components of the 4S3/2 manifold of the Er3+ ions, we achieve thermal sensitivities up to 1.22% K-1 at 100 K and temperature resolutions reaching 0.6 K. Our results further experimentally confirm recently published theoretical predictions, demonstrating that thermometric performance is not directly dependent on the peak energy separation of the resulting spectral lines of the involved electronic energy levels when using individual Stark transitions to evaluate the LIR. The proposed procedure gives an energy gap calibration that matches the one determined by sample spectroscopy for nonoverlapping lines in the luminescence spectrum. These insights provide a robust foundation for the design of high-performance cryogenic thermometers based on rare-earth-doped materials.
Related Concept Videos
06:00Biological Samples Preparation for Speciation at Cryogenic Temperature using High-Resolution X-Ray Absorption Spectroscopy
09:50Measuring the Densities of Aqueous Glasses at Cryogenic Temperatures
Dean-Stark Trap
A Dean-Stark trap is a special piece of glassware, which allows the collection of water during a reaction through an azeotropic distillation. The desire to collect water from a reaction can have various reasons. It can drive the equilibria in reactions, where water is formed as a byproduct. According to Le Chatelier's principle, a change in temperature, pressure, concentration, or volume will...
06:42Preparation of Zinc Oxide Nanoparticles and the Evaluation of their Antibacterial Effects
05:41Photochemical Oxidative Growth of Iridium Oxide Nanoparticles on CdSe@CdS Nanorods
07:24Visible-light Induced Reduction of Graphene Oxide Using Plasmonic Nanoparticle