A Comparative, Multiobserver Analysis of Nodal Contouring Methods in Pelvic Online Cone Beam-Based Adaptive Radiation
Ethan Wang1, Michael Dohopolski1, Allen Yen1
1Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas.
Purpose:
In online cone beam computed tomography (CBCT)-based adaptive radiation therapy (ART), nodal recontouring ensures sufficient nodal coverage by accounting for anatomic change but is uniquely challenging due to small target size and time pressure. This study evaluates the accuracy of rigid propagation versus artificial intelligence-guided deformation (AID) for nodal autosegmentation via comparison to nodal recontours delineated with unlimited time (ie, benchmark contours).
Methods And Materials:
We analyzed 25 nodal structures from 16 patients receiving pelvic online CBCT-based ART with nodal boost. Nodal structure sampling was informed by an initial power analysis. For each structure, we obtained rigidly propagated and AID-generated contours in addition to 2 benchmark contours and the clinical contour used in adapted plan generation. We calculated dice similarity coefficient (DSC), false-positive dice, false-negative dice, and 95% Hausdorff distance (HD95) between clinical, propagated, and AID contours against benchmark pairs and DSC and HD95 between benchmark pairs. The failure rate of nonbenchmark contours relative to benchmark pairs was calculated as the proportion of contours with an HD95 > 5 mm. We calculated the normalized D100, normalized D95, V100, and V95 of the adapted plan dose over all contours. Clinical tumor volume contours were used for all comparisons.
Results:
Median DSC versus benchmark contours were 0.68 for rigidly propagated and 0.58 for AID contours. A significant difference in false-negative dice (P = .01, Cohen's d 0.806) was identified in benchmark-to-propagated versus benchmark-to-AID comparison. The failure rate of rigidly propagated, AID, and clinical contours was 20%, 48%, and 28% respectively. The median DSC between benchmark contours was 0.75. No significant differences across dose metrics were identified between contour types.
Conclusions:
Rigid propagation is superior to AID for initial contour generation in pelvic CBCT-based ART. Increased contouring time and image quality may improve contour quality and reduce interobserver variability but may be limited by the influence of individual contouring preferences.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Related Concept Videos
08:17Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Nodal Analysis
Consider, for instance, a simple circuit composed of three nodes and three resistors, as shown in...
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
05:49Reliability of Artificial Intelligence-Based Cone Beam Computed Tomography Integration with Digital Dental Images
06:18The Collective Trust Game: An Online Group Adaptation of the Trust Game Based on the HoneyComb Paradigm