Background:
Computed tomography (CT) scan is a good and noninvasive prediction tool for eosinophilic chronic rhinosinusitis with nasal polyps (eCRSwNP), and how to choose the appropriate CT parameter is crucial-especially because there have not been unanimous histopathologic criteria to diagnose eCRSwNP.
Objective:
This study sought to select the suitable CT parameter to predict eCRSwNP in different criteria.
Method:
This retrospective study included 147 CRSwNP patients who underwent a sinus CT scan and histopathological examination. Nine common CT parameters and 5 representative criteria of eCRSwNP (>5/HPF, >10/HPF, >70/HPF, >10%/HPF and >20%/HPF) were adopted. Logistic regression analysis and ROC analysis were performed to evaluate the predictive value of CT parameters.
Result:
Among the 9 CT parameters, olfactory cleft (OC) score, ethmoid sinus and maxillary sinus ratio (E/M ratio), and posterior ethmoid (PE) score were significantly associated with eCRSwNP. In the 5 representative criteria of eCRSwNP, all the results showed that the OC score was not only the significant predictor in the univariate analysis, but also the most significant one in the multivariate analysis. Meanwhile, both OC score and E/M ratio were included in the multivariable logistic regression model. The clinically convenient cut-off points of model were OC score >2 and E/M ratio >2.5.
Conclusion:
The OC score, E/M ratio, and PE score were significantly associated with eosinophilia of nasal polyp tissue. Therein, OC score was the best marker to predict eCRSwNP among the 5 representative criteria. The combination of OC score and E/M ratio can obtain a better predictive value of eCRSwNP.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
06:56Tree Core Analysis with X-ray Computed Tomography
04:40Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Imaging Studies III: Computed Tomography
Visualization of a Cerebral Thrombus in a Mouse Using Micro-Computed Tomography Imaging
07:013D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography