Related Experiment Video
Updated: Jan 20, 2026

3D Cine Magnetic Resonance Imaging of Respiratory Motion in Mechanically Ventilated Mice and Rats
Published on: September 19, 2025
Humeral head deviation and velocity in multidirectional instability of the glenohumeral joint: a cine magnetic
Kazuhisa Matsui1, Takashi Tachibana2, Katsuya Nobuhara3
1Department of Physical Therapy, Faculty of Medical Science, Nagoya Aoi University, Nagoya-shi, Aichi-ken, Japan.
Background:
Manual clinical tests for shoulder instability rely heavily on subjective assessments of humeral head translation, making objective quantification challenging. This study hypothesized that patients with multidirectional glenohumeral instability (MDI) would demonstrate greater humeral head deviation and faster deviation velocity than healthy controls during active shoulder rotation, as assessed using cine magnetic resonance imaging (MRI).
Methods:
Fourteen participants (eight shoulders with MDI and 20 healthy shoulders) underwent cine MRI while performing active shoulder rotation with the arm at the side. Humeral head deviation, deviation amplitude, and deviation velocity were calculated and compared between the groups using Welch's t-test.
Results:
The MDI group showed significantly greater humeral head deviation, wider amplitude of deviation, and faster deviation velocity than the control group (P = .008 for anterior deviation, P = .009 for posterior deviation). The deviation amplitude exceeded 35% of the glenoid width in MDI shoulders, surpassing established clinical thresholds.
Conclusion:
Patients with MDI demonstrated quantifiable dynamic instability on cine MRI. This modality may provide objective support for clinical findings. However, validation in larger cohorts is warranted to confirm these findings, given the limited number of MDI shoulders (n = 8).
Related Concept Videos
08:223D Cine Magnetic Resonance Imaging of Respiratory Motion in Mechanically Ventilated Mice and Rats
Cardiac Magnetic Resonance Imaging
In this video, high field, small-bore magnetic resonance imaging (MRI) with physiological monitoring is demonstrated to acquire gated cine loops of the murine cardiovascular system. This procedure provides a basis for assessing left-ventricular function, visualizing vascular networks, and quantifying motion of organs due to respiration. Comparable small animal...
09:14Cardiac Magnetic Resonance Imaging at 7 Tesla
09:30Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
07:02Phase Contrast Magnetic Resonance Imaging in the Rat Common Carotid Artery
fMRI: Functional Magnetic Resonance Imaging